Schneider Electric ATV320D11N4C variable speed drive, Altivar Machine ATV320, 11kW, 380 to 500V, 3 phases, compact
Code: SCHATV320D11N4C
Unit of measure:
EACH
Description
ATV320 11KW 400V 3PH COMPACT
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
| With safety function Safe brake management (SBC/SBT) | false |
| With safety function Safe Speed Monitor (SSM) | false |
| Maximum deflection under vibratory load (during operation) | 1.5mm at 2...13 Hz |
| Line current | 25.6 A at 500 V (heavy duty) |
| Environmental class (during storage) | class 1S2 according to EN 60721-3 |
| Supporting protocol for Data-Highway | false |
| Operating element present | true |
| Ambient air temperature for operation | 50-60 °C with derating factor |
| Minimum switching current | relay output R1A- R1B- R1C- R2A- R2C: 5 mA at 24 V DC |
| Supporting protocol for EtherNet/IP | true |
| Switching frequency | 4...16 kHz with derating factor |
| Analogue output type | software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm- resolution 10 bits |
| Ambient air temperature for storage | -25-70 °C |
| Number of input phases | 3 |
| Discrete output type | open collector DQ- 0-1 kHz 30 V DC 100 mA |
| Apparent power | 22.2 kVA at 500 V (heavy duty) |
| Power dissipation in W | fan: 370 W at 380 V- switching frequency 4 kHz |
| Sampling duration | 2 ms (AQ1) - analog output |
| Brake chopper integrated | true |
| Discrete input number | 7 |
| Protection type | overcurrent between output phases and earth: drive |
| Encoder protocol | RS 422 |
| Relative symmetric mains voltage tolerance | 10 % |
| Motor power kW | 11 kW for heavy duty |
| Supporting protocol for DeviceNet | true |
| With safety function Safely Limited Position (SLP) | false |
| Supporting protocol for INTERBUS-Safety | false |
| Supporting protocol for Foundation Fieldbus | false |
| Supporting protocol for PROFINET IO | true |
| Variant | standard version |
| Application in domestic and commercial area permitted | false |
| Computer port | true |
| Maximum input current | 36.6 A |
| 4 quadrant operation possible | true |
| Option card | communication module- Profibus DP V1 |
| Pollution degree | 2 |
| Prospective line Isc | 22 kA |
| Number of HW interfaces serial RS232 | 0.0 |
| With sft fct Safe Stop 2 (SS2) | false |
| Supporting protocol for TCP/IP | true |
| Permitted relative humidity (during transport) | class 2K5 according to EN 60721-3 |
| With safety function Safely Limited Speed (SLS) | true |
| Number of HW interfaces serial TTY | 0.0 |
| Product specific application | complex machines |
| Discrete input logic | negative logic (sink) |
| With safety function Safe torque off (STO) | true |
| Depth | 198.0mm |
| Application in industrial area permitted | true |
| Supporting protocol for INTERBUS | false |
| Design of frequency changer | U converter |
| Volume of cooling air | 156.0 m3/h |
| Supporting protocol for LON | false |
| Linearity error | AQ1: +/- 0.3 % for analog output |
| Housing material | plastic |
| Number of output phases | 3 |
| Maximum deflection under vibratory load (during transport) | 3.5mm at 2...13 Hz |
| Width | 180mm |
| Supporting protocol for SafetyBUS P | false |
| Ambient air transport temperature | -25-70 °C |
| Capacity of DC link | 1410 µF |
| Nominal output current | 27.7 A |
| NEMA degree of protection | NEMA 1 |
| Power loss static current independent | 370 W |
| Maximum acceleration under vibratory load (during storage) | 10 m/s² at 13...200 Hz |
| Method of access | slave CANopen |
| Permitted relative humidity (during operation) | class 3K5 according to EN 60721-3 |
| Maximum output voltage | 500 V |
| Speed accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn |
| Analogue output number | 1 |
| Supporting protocol for BACnet | false |
| Number of HW interfaces parallel | 0.0 |
| Motor slip compensation | not available in voltage/frequency ratio (2 or 5 points) |
| Environmental class (during operation) | class 3S2 according to IEC 60721-3-3 |
| Analogue input number | 3 |
| Number of inputs- potential-free | 0 |
| Discrete input type | DI1...DI6 logic inputs- 24 V DC (30 V) |
| Net weight | 6.8 kg |
| Synchronous motor control profile | vector control without sensor |
| Refresh time | relay output (R1A- R1B- R1C): 2 ms |
| Asynchronous motor control profile | voltage/frequency ratio - Energy Saving- quadratic U/f |
| Supporting protocol for DeviceNet Safety | false |
| Supporting protocol for SUCONET | false |
| EMC filter | integrated |
| [Us] rated supply voltage | 380...500 V - 15...10 % |
| With safety function Safe Stop 1 (SS1) | true |
| Operating position | vertical +/- 10 degree |
| Supporting protocol for ASI | false |
| Electromagnetic compatibility | electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 |
| Permitted relative humidity (during storage) | class 1K5 according to EN 60721-3 |
| Nominal switching frequency | 4 kHz |
| Supporting protocol for KNX | false |
| Environmental class (during transport) | class 2S1 according to EN 60721-3 |
| With safety function Safe Direction (SDI) | false |
| Number of HW interfaces USB | 0.0 |
| Relative symmetric network frequency tolerance | 5 % |
| Mounting mode | wall mount |
| Supplier Code | ATV320D11N4C |
| Number of HW interfaces serial RS422 | 0.0 |
| Supporting protocol for SERCOS | false |
| Network frequency | 50...60 Hz |
| With safety function Safe Operating Stop (SOS) | false |
| Supporting protocol for other bus systems | true |
| Network number of phases | 3 phases |
| With safety function Safe Position (SP) | false |
| Analogue input type | AI2 bipolar differential voltage: +/- 10 V DC- impedance: 30 kOhm- resolution 10 bits |
| Maximum acceleration under shock load (during transport) | 150 m/s² at 11 ms |
| Communication port protocol | CANopen |
| IP degree of protection | IP20 |
| Range | Altivar Machine ATV320 |
| Overvoltage category | III |
| Optical interface present | false |
| Number of inputs- bidirectional- not potential-free | 0 |
| EMC limit value (complied) | true |
| 1 phase low current possible | false |
| Acceleration and deceleration ramps | acceleration/deceleration automatic stop with DC injection |
| Nominal output power | 11 kW |
| Maximum acceleration under vibratory load (during transport) | 10 m/s² at 13...200 Hz |
| Base load current at high overload | 27.7 A |
| Accuracy | +/- 0.5 % AI1- AI2- AI3 for a temperature of 25 °C analog input |
| Supporting protocol for CAN | true |
| Power loss per device current dependent | 370 W |
| Supporting protocol for PROFINET CBA | false |
| Maximum switching current | relay output R2A- R2C on resistive load- cos phi = 1 : 5 A at 30 V DC |
| Height | 330mm |
| Number of HW interfaces serial RS485 | 1.0 |
| Relay output type | configurable relay logic R1C |
| Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
| Supporting protocol for PROFIBUS | true |
| Number of HW interfaces PROFINET | 0.0 |
| Regulation loop | adjustable PID regulator |
| Maximum output frequency | 0.599 kHz |
| Number of HW interfaces other | 1.0 |
| Format of the drive | compact |
| Discrete output number | 3 |
| Maximum associated fuse rating | 63.0 A |
| Marking | CSA |
| Maximum deflection under vibratory load (during storage) | 3.5mm at 2...13 Hz |
| Supporting protocol for PROFIsafe | false |
| Standards | IEC 61800-5-1 |
| With safety function Safe programmable logic | false |
| Product certifications | RCM |
| Brand Name | Schneider Electric |
| Braking to standstill | by DC injection |
| Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
| Supporting protocol for AS-Interface Safety at Work | false |
| Number of HW interfaces industrial Ethernet | 0.0 |
| Supporting protocol for MODBUS | true |
| Transient overtorque | 170-200 % of nominal motor torque |
| Maximum acceleration under shock load (during storage) | 150 m/s² at 11 ms |
| Product or component type | variable speed drive |