| Product destination | synchronous motors |
| With safety function Safe brake management (SBC/SBT) | false |
| Relative humidity | 5-95 % without condensation conforming to IEC 60068-2-3 |
| Data format | 8 bits- configurable odd- even or no parity |
| With safety function Safe Speed Monitor (SSM) | false |
| Maximum deflection under vibratory load (during operation) | 1.5mm at 2...13 Hz |
| Line current | 35.8 A at 480 V (heavy duty) |
| Environmental class (during storage) | class 1S2 according to EN 60721-3-1 |
| Supporting protocol for Data-Highway | false |
| Operating element present | true |
| Ambient air temperature for operation | 50-60 °C (with derating factor) |
| Connector type | RJ45 (on the remote graphic terminal) for Modbus serial |
| Minimum switching current | relay output R1- R2- R3: 5 mA at 24 V DC |
| Electrical connection | line side: screw terminal 25...50mm²/AWG 4...AWG 1 |
| Supporting protocol for EtherNet/IP | true |
| Switching frequency | 4...12 kHz with derating factor |
| Analogue output type | software-configurable current DQ-- DQ+: 100 mA |
| Motor starter type | variable speed drive |
| Output voltage | <= power supply voltage |
| Ambient air temperature for storage | -40-70 °C |
| Number of input phases | 3 |
| Number of addresses | 1-247 for Modbus serial |
| Discrete output type | relay outputs R2A- R2C 250 V AC 5000 mA |
| Apparent power | 29.8 kVA at 480 V (heavy duty) |
| Frequency resolution | analog input: 0.012/50 Hz |
| Power dissipation in W | forced convection: 640 W at 380 V- switching frequency 4 kHz |
| Exchange mode | half duplex- full duplex- autonegotiation Ethernet/Modbus TCP |
| Sampling duration | 5 ms +/- 0.1 ms (AI1- AI2- AI3) - analog input |
| Brake chopper integrated | false |
| Discrete input number | 8 |
| Protection type | safe torque off: motor |
| Relative symmetric mains voltage tolerance | 10 % |
| Motor power kW | 22 kW (heavy duty) |
| Supporting protocol for DeviceNet | false |
| Quantity per set | 1 |
| With safety function Safely Limited Position (SLP) | false |
| Supporting protocol for INTERBUS-Safety | false |
| Supporting protocol for Foundation Fieldbus | false |
| Supporting protocol for PROFINET IO | true |
| Variant | standard version |
| Application in domestic and commercial area permitted | false |
| Computer port | true |
| Maximum input current | 53.3 A |
| 4 quadrant operation possible | false |
| Local signalling | 4 LEDs (dual colour) for communication module status |
| Option card | communication module- Ethernet Powerlink |
| Pollution degree | 2 conforming to IEC 61800-5-1 |
| Prospective line Isc | 50 kA |
| Number of HW interfaces serial RS232 | 0 |
| With sft fct Safe Stop 2 (SS2) | false |
| Supporting protocol for TCP/IP | true |
| Permitted relative humidity (during transport) | class 2K5 according to EN 60721-3 |
| With safety function Safely Limited Speed (SLS) | false |
| Number of HW interfaces serial TTY | 0 |
| Discrete and process manufacturing | food and beverage processing atomization |
| Supply | internal supply for digital inputs and STO: 24 V DC (21-27 V)- <200 mA- protection type: overload and short-circuit protection |
| Input compatibility | STOA- STOB: discrete input level 1 PLC conforming to IEC 61131-2 |
| Product specific application | process and utilities |
| Enclosure mounting | wall mounted |
| Discrete input logic | negative logic (sink) (DI1...DI8)- > 16 V (state 0)- < 10 V (state 1) |
| With safety function Safe torque off (STO) | true |
| Depth | 271mm |
| Application in industrial area permitted | true |
| Supporting protocol for INTERBUS | false |
| Design of frequency changer | U converter |
| Volume of cooling air | 240 m3/h |
| Supporting protocol for LON | false |
| Linearity error | AO1- AO2: +/- 0.2 % for analog output |
| Housing material | plastic |
| Number of output phases | 3 |
| Maximum deflection under vibratory load (during transport) | 1.5mm at 2...13 Hz |
| Width | 226mm |
| Supporting protocol for SafetyBUS P | false |
| Ambient air transport temperature | -40-70 °C |
| Operating altitude | 1000...4800 m with current derating 1 % per 100 m |
| Capacity of DC link | 2500.0 µF |
| Nominal output current | 61.5 A |
| Device short name | ATV630 |
| NEMA degree of protection | NEMA 1 |
| Power loss static current independent | 31.0 W |
| Maximum acceleration under vibratory load (during storage) | 10 m/s² at 13...200 Hz |
| Method of access | slave Modbus TCP |
| Permitted relative humidity (during operation) | class 3K5 according to EN 60721-3 |
| Maximum output voltage | 480.0 V |
| Analogue output number | 2 |
| Relay output number | 3 |
| Supporting protocol for BACnet | false |
| Number of HW interfaces parallel | 0 |
| Transmission frame | RTU |
| Motor slip compensation | can be suppressed |
| Supply frequency | 50...60 Hz - 5...5 % |
| Environmental class (during operation) | class 3S3 according to IEC 60721-3-3 |
| Analogue input number | 3 |
| Number of inputs- potential-free | 0 |
| Discrete input type | DI7- DI8 programmable as pulse input: 0-30 kHz- 24 V DC (<= 30 V) |
| Transmission rate | 4800 bps- 9600 bps- 19200 bps- 38.4 Kbps |
| Net weight | 28 kg |
| Specific application | utility |
| Synchronous motor control profile | synchronous reluctance motor |
| Refresh time | relay output (R1- R2- R3): 5 ms (+/- 0.5 ms) |
| Asynchronous motor control profile | optimized torque mode |
| Supporting protocol for DeviceNet Safety | false |
| Supporting protocol for SUCONET | false |
| Maximum THDI | <48 % from 80...100 % of load conforming to IEC 61000-3-12 |
| EMC filter | integrated with 150 m conforming to IEC 61800-3 category C3 |
| [Us] rated supply voltage | 380...480 V - 15...10 % |
| With safety function Safe Stop 1 (SS1) | false |
| Operating position | vertical +/- 10 degree |
| Supporting protocol for ASI | false |
| Electromagnetic compatibility | 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 |
| Maximum transient current | 69.5 A during 60 s (heavy duty) |
| Permitted relative humidity (during storage) | class 1K5 according to EN 60721-3 |
| Nominal switching frequency | 4 kHz |
| Supporting protocol for KNX | false |
| Noise level | 63.5 dB |
| Environmental class (during transport) | class 2S1 according to EN 60721-3-2 |
| Base load current at low overload | 61.5 A |
| With safety function Safe Direction (SDI) | false |
| Number of HW interfaces USB | 0 |
| Relative symmetric network frequency tolerance | 5 % |
| Mounting mode | wall mount |
| Supplier Code | ATV630D30N4 |
| Number of HW interfaces serial RS422 | 0 |
| Supporting protocol for SERCOS | false |
| Network frequency | 50...60 Hz |
| Type of polarization | no impedance |
| Vibration resistance | 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6 |
| With safety function Safe Operating Stop (SOS) | false |
| Supporting protocol for other bus systems | false |
| Network number of phases | 3 phases |
| With safety function Safe Position (SP) | false |
| Analogue input type | AI2 voltage analog input: - 10...10 V DC- impedance: 31.5 kOhm- resolution 12 bits |
| Shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
| Maximum acceleration under shock load (during transport) | 150 m/s² at 11 ms |
| Insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth |
| Communication port protocol | Modbus TCP |
| Degree of protection | UL type 1 conforming to UL 508C |
| IP degree of protection | IP21 |
| Range | Altivar Process ATV600 |
| Overvoltage category | III |
| Optical interface present | false |
| Number of inputs- bidirectional- not potential-free | 0 |
| Functionality | full |
| EMC limit value (complied) | true |
| 1 phase low current possible | false |
| Acceleration and deceleration ramps | linear adjustable separately from 0.01...9999 s |
| Nominal output power | 30.0 kW |
| Maximum acceleration under vibratory load (during transport) | 10 m/s² at 13...200 Hz |
| Power range | 30-50 kW at 480-500 V 3 phases |
| Base load current at high overload | 46.3 A |
| Accuracy | +/- 1 % AO1- AO2 for a temperature variation 60 °C analog output |
| Supporting protocol for CAN | true |
| Power loss per device current dependent | 843.0 W |
| Supporting protocol for PROFINET CBA | true |
| Maximum switching current | relay output R1- R2- R3 on inductive load- cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
| Height | 673mm |
| Number of HW interfaces serial RS485 | 1 |
| Relay output type | configurable relay logic R3: sequence relay NO electrical durability 100000 cycles |
| Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
| Supporting protocol for PROFIBUS | true |
| Continuous output current | 46.3 A at 4 kHz for heavy duty |
| Number of HW interfaces PROFINET | 0 |
| Type of cooling | forced convection |
| Regulation loop | adjustable PID regulator |
| Maximum output frequency | 500 kHz |
| Number of HW interfaces other | 0 |
| Discrete output number | 0 |
| Maximum associated fuse rating | 100.0 A |
| Safety function | STO (safe torque off) SIL 3 |
| Marking | CE |
| Maximum deflection under vibratory load (during storage) | 1.5mm at 2...13 Hz |
| Supporting protocol for PROFIsafe | false |
| Standards | IEC 61508 |
| With safety function Safe programmable logic | false |
| Product certifications | ATEX zone 2/22 |
| Brand Name | Schneider Electric |
| Braking to standstill | by DC injection |
| Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
| Supporting protocol for AS-Interface Safety at Work | false |
| Motor power hp | 30 hp heavy duty |
| Number of HW interfaces industrial Ethernet | 1 |
| Isolation | between power and control terminals |
| Supporting protocol for MODBUS | true |
| Physical interface | 2-wire RS 485 |
| Speed drive output frequency | 0.1-500 Hz |
| Maximum acceleration under shock load (during storage) | 150 m/s² at 11 ms |
| Product or component type | variable speed drive |