Schneider Electric C1634V160 Trip unit MicroLogic Vigi 4.2, ComPacT NSX160/250, 3 poles, electronic basic and earth leakage protections, 160A rating
Code: SCHC1634V160
Unit of measure:
EACH
Description
TRIP UNIT NSX160 AC 3P3D 160A 4.2
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
| [Δt] residual earth-leakage time delay adjustment | 150-150 ms |
| Operating mode | OFF using the IΔn rotary switch |
| Long time pick-up adjustment type Ir | adjustable 9 settings |
| [In] rated current | 160 A at 40 °C |
| Ambient air temperature for operation | -25-70 °C |
| Instantaneous pick-up adjustment type Ii | fixed |
| Earth-leakage protection | integrated |
| Mounting mode | fixed |
| Residual earth-leakage sensitity adjustment type | adjustable |
| Supplier Code | C1634V160 |
| Instantaneous pick-up adjustment range | 2400 A |
| Residual earth-leakage time delay adjustment type | adjustable |
| Zone selective interlocking ZSI | without |
| Ambient air temperature for storage | -40-85 °C |
| Poles description | 3P |
| Trip unit name | MicroLogic 4.2 |
| Network frequency | 50/60 Hz |
| [Isd] short-time pick-up adjustment range | 1.5...10 x Ir |
| Short-time delay adjustment type | fixed |
| Trip unit protection functions | LSoIR |
| Thermal memory | 20 minutes before and after tripping |
| Protected poles description | 3D |
| Protection type | I : for instantaneous short-circuit protection |
| Network type | AC |
| Trip unit technology | electronic |
| Device application | distribution |
| [Ue] rated operational voltage | 440 V AC 50/60 Hz |
| IP degree of protection | IP40 conforming to IEC 60529 |
| Range | ComPacT new generation |
| Standards | EN/IEC 60947-2 |
| Long time pick-up adjustment range | 63...160 A |
| Brand Name | Schneider Electric |
| Electrical shock protection class | class II |
| [tr] long-time delay adjustment range | 16-16 s at 6 x Ir |
| Range compatibility | ComPacT new generation NSX250 |
| Local signalling | LED 90 % Ir (orange) for overload |
| [IΔn] residual earth-leakage sensitive adjustment | 1-1 A |
| Pollution degree | 3 conforming to IEC 60947-1 |
| Long time delay adjustment type | fixed |
| Short-time pick-up adjustment type Isd | adjustable |
| Earth-leakage protection class | class A |
| Product or component type | trip unit |
We would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
Can't find what you're looking for?
Request now