Schneider Electric LC1G185BEEA High power contactor, TeSys Giga, 3 pole (3NO), AC-3 <=440V 185A, advanced version, 24…48V wide band AC/DC coil, Dark Grey
Code: SCHLC1G185BEEA
Unit of measure:
EACH
Description
CONTACTORTESYSGIGA185 3P ADV 24-48V ACDC
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
| Contactor application | motor control |
| Hold-in power consumption in W | 5.7-5.7 W |
| Maximum operating rate | 600 cyc/h AC-3e |
| Number of modules per PLC per PC | 1 |
| Ambient air temperature for operation | -25-60 °C |
| Irms rated making capacity | 2310 A at 440 V |
| [Ith] conventional free air thermal current | 305 A (at 40 °C) |
| Supplier Code | LC1G185BEEA |
| Ambient air temperature for storage | -60-80 °C |
| [Icw] rated short-time withstand current | 0.4 kA - 10 min |
| Inrush power in W | 220 W |
| Inrush power in VA | 290-290 VA |
| Hold-in power consumption in VA | 10-10 VA |
| Motor power kW | 90 kW at 400 V AC 50/60 Hz (AC-3) |
| Safety reliability level | B10d = 3000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| IP degree of protection | IP2X front face with shrouds conforming to VDE 0106 |
| Range | TeSys |
| Overvoltage category | III |
| Electrical durability | 150 cycles AC-4 at Ue 400 V |
| Protective treatment | TH |
| Tightening torque | 18 N.m |
| Average impedance | 0.00017 Ohm |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Ie] rated operational current | 185 A (at <60 °C) at <= 440 V AC-3 |
| Connections - terminals | control circuit: push-in 0.75-2.5mm² - cable stiffness: flexible with cable end |
| Associated fuse rating | 160 A aM at <= 690 V for motor |
| Depth | 193mm |
| Connection pitch | 35mm |
| Colour | Dark Grey |
| Mounting support | plate |
| Pole contact composition | 3 NO |
| Mechanical durability | 8 Mcycles |
| Permissible ambient air temperature around the device | -40-70 °C at Uc |
| Coil technology | built-in bidirectional peak limiting |
| Height | 255mm |
| Poles description | 3P |
| Width | 108mm |
| Operating time | 15...50 ms opening |
| Device short name | LC1G |
| [Uc] control circuit voltage | 24...48 V DC |
| Compatibility code | LC1G |
| Mechanical robustness | shocks 15 gn 11 ms contactor closed |
| [Ue] rated operational voltage | <= 460 V DC |
| [Ui] rated insulation voltage | 1000 V |
| Standards | IEC 60335-2-40:Annex JJ |
| Control circuit voltage limits | drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C) |
| Product certifications | UKCA |
| Brand Name | Schneider Electric |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Power dissipation per pole | 6 W AC-3 - Ith 185 A |
| Motor power hp | 150 hp at 575/600 V 60 Hz |
| Rated breaking capacity | 1610 A at 440 V |
| Utilisation category | AC-3e |
| Net weight | 4.1 kg |
| Product or component type | contactor |
We would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
Can't find what you're looking for?
Request now
We can source just about anything, submit a request and we'll get back to you soon.