Schneider Electric LC1G400KUEN High power contactor, TeSys Giga, 3 pole (3NO), AC-3 <=440V 400A, standard version, 100…250V wide band AC/DC coil, Dark Grey
Code: SCHLC1G400KUEN
Unit of measure:
EACH
Description
CONTACTORTESYSGIGA400 3PSTD100-250V ACDC
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
Contactor application | power switching |
Hold-in power consumption in W | 9.3-9.3 W |
Maximum operating rate | 600 cyc/h AC-3e |
Number of modules per PLC per PC | 0 |
Ambient air temperature for operation | -25-60 °C |
Irms rated making capacity | 5090 A at 440 V |
[Ith] conventional free air thermal current | 550 A (at 40 °C) |
Supplier Code | LC1G400KUEN |
Ambient air temperature for storage | -60-80 °C |
[Icw] rated short-time withstand current | 2.4 kA - 30 s |
Inrush power in W | 660 W |
Inrush power in VA | 750-750 VA |
Hold-in power consumption in VA | 15.5-15.5 VA |
Motor power kW | 250 kW at 500 V AC 50/60 Hz (AC-4) |
Safety reliability level | B10d = 3000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
IP degree of protection | IP2X front face with shrouds conforming to VDE 0106 |
Range | TeSys |
Overvoltage category | III |
Electrical durability | 150 cycles AC-4 at Ue 400 V |
Protective treatment | TH |
Tightening torque | 35 N.m |
Average impedance | 0.0001 Ohm |
Auxiliary contact composition | 1 NO + 1 NC |
[Ie] rated operational current | 400 A (at <60 °C) at <= 440 V AC-3 |
Connections - terminals | control circuit: push-in 2 0.5-1.0mm² with cable end |
Associated fuse rating | 630 A gG at <= 690 V |
Depth | 226mm |
Connection pitch | 45mm |
Colour | Dark Grey |
Mounting support | plate |
Pole contact composition | 3 NO |
Mechanical durability | 8 Mcycles |
Permissible ambient air temperature around the device | -40-70 °C at Uc |
Coil technology | built-in bidirectional peak limiting |
Height | 225mm |
Poles description | 3P |
Width | 140mm |
Operating time | 15...50 ms opening |
Device short name | LC1G |
[Uc] control circuit voltage | 100...250 V DC |
Compatibility code | LC1G |
Mechanical robustness | shocks 10 gn 11 ms contactor open |
[Ue] rated operational voltage | <= 460 V DC |
[Ui] rated insulation voltage | 1000 V |
Standards | UL 60335-1 |
Control circuit voltage limits | drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C) |
Product certifications | EU-RO-MR by DNV-GL |
Brand Name | Schneider Electric |
[Uimp] rated impulse withstand voltage | 8 kV |
Power dissipation per pole | 16 W AC-3 - Ith 400 A |
Motor power hp | 400 hp at 575/600 V 60 Hz |
Rated breaking capacity | 3480 A at 440 V |
Utilisation category | AC-4 |
Net weight | 7.5 kg |
Product or component type | contactor |
We would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
Can't find what you're looking for?
Request now
We can source just about anything, submit a request and we'll get back to you soon.