Schneider Electric LC1K1601U7 contactor, TeSys K, 3P, AC-3 <=440V 16A, aux. 1NC, 230...240V AC coil
				
				
					Code: SCHLC1K1601U7
				
				
				
					
						Unit of measure:
						EACH
							
				
				Description
						3P CONT 16A AC3 7.5KW 1NC AUX 240VAC COI
				Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
| Contactor application | motor control | 
| Maximum operating rate | 3600 cyc/h | 
| Ambient air temperature for operation | -25-50 °C | 
| Minimum switching current | 5 mA for signalling circuit | 
| Non overlap distance | 0.5mm | 
| Irms rated making capacity | 110 A AC for signalling circuit conforming to IEC 60947 | 
| Signalling circuit frequency | <= 400 Hz | 
| [Ith] conventional free air thermal current | 10 A (at 50 °C) for signalling circuit | 
| Supplier Code | LC1K1601U7 | 
| Ambient air temperature for storage | -50-80 °C | 
| [Icw] rated short-time withstand current | 75 A 50 °C - 30 s for power circuit | 
| Inrush power in VA | 30-30 VA (at 20 °C) | 
| Hold-in power consumption in VA | 4.5-4.5 VA (at 20 °C) | 
| Safety reliability level | B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | 
| Motor power kW | 7.5 kW at 380...415 V AC 50/60 Hz AC-3 | 
| Insulation resistance | > 10 MOhm for signalling circuit | 
| IP degree of protection | IP2X conforming to VDE 0106 | 
| Range | TeSys | 
| Flame retardance | V1 conforming to UL 94 | 
| Overvoltage category | III | 
| Electrical durability | 1.3 Mcycles 16 A AC-3e at Ue <= 440 V | 
| Protective treatment | TC conforming to DIN 50016 | 
| Tightening torque | 0.8-1.3 N.m - on screw clamp terminals pozidriv No 2 | 
| Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit | 
| Auxiliary contact composition | 1 NC | 
| [Ie] rated operational current | 16 A (at <60 °C) at <= 440 V AC AC-3e for power circuit | 
| Connections - terminals | screw clamp terminals 1 cable(s) 0.34-2.5mm²flexible with cable end | 
| Control circuit type | AC at 50/60 Hz | 
| Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947 | 
| Depth | 57mm | 
| Mounting support | plate | 
| Pole contact composition | 3 NO | 
| Mechanical durability | 10 Mcycles | 
| Minimum switching voltage | 17 V for signalling circuit | 
| Height | 58mm | 
| Poles description | 3P | 
| Width | 45mm | 
| Operating altitude | 2000 m without derating | 
| Operating time | 10...20 ms coil energisation and NO closing | 
| Device short name | LC1K | 
| [Uc] control circuit voltage | 230...240 V AC 50/60 Hz | 
| Compatibility code | LC1K | 
| Auxiliary contacts type | type instantaneous 1 NC | 
| Mechanical robustness | shocks contactor closed- on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 | 
| Device application | control | 
| [Ue] rated operational voltage | signalling circuit: <= 690 V AC <= 400 Hz | 
| [Ui] rated insulation voltage | signalling circuit: 690 V conforming to IEC 60947-5-1 | 
| Standards | CSA C22.2 No 60947-4-1 | 
| Control circuit voltage limits | drop-out: >= 0.20 Uc (at <50 °C) | 
| Product certifications | EAC | 
| Brand Name | Schneider Electric | 
| Heat dissipation | 1.3-1.3 W | 
| [Uimp] rated impulse withstand voltage | 8 kV | 
| Rated breaking capacity | 70 A at 660...690 V conforming to IEC 60947 | 
| Utilisation category | AC-3e | 
| Net weight | 0.18 kg | 
| Product or component type | contactor | 
We would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
Can't find what you're looking for?
        Request now
      We can source just about anything, submit a request and we'll get back to you soon.
 
                  
              