Description
Schneider Electric METSEPM5310 power meter PowerLogic PM5310, modbus, up to 31st Harmonic, 256KB 2DI/2DO 35 alarms
This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 64 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to the 31st Harmonic. Include 256 kiloBytes of memory for two fixed parameters, active and reactive energy. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 415 VAC and 125 to 250 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 35 to 690 VAC at 47 to 63 Hz. Measurement range between Phase and Neutral is 20 to 400VAC at 47 to 63 Hz. Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support. The meter also has two digital inputs or digital outputs, configurable. There are 35 configurable alarms and it supports four tariff schedules. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 2.83 inches (72 millimetres), height 3.78 inches (96 millimetres) and product weight 15.2 onces (430 g).
Features:
• Digital input and output for WAGES monitoring and control
• Modbus 485 communication port for remote monitoring
• Identify energy savings opportunties with precision accuracy of Class 0.5S
• 31st Hamronic measurement for Power Quality management
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
| Relative humidity | 5-95 % at 50-50 °C non-condensing |
| [Us] rated supply voltage | 100...300 V DC |
| Frequency measurement range | 45-65 Hz |
| Data recording | data logs |
| Electromagnetic compatibility | voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
| Ambient air temperature for operation | -20-70 °C display |
| Communication port support | RS485 |
| Mounting mode | flush-mounted |
| Number of outputs | 2 digital |
| Supplier Code | METSEPM5310 |
| Ambient air temperature for storage | -40-85 °C |
| Network frequency | 60 Hz |
| Analogue input type | current (impedance <= 0.3 mOhm) |
| Maximum power consumption in VA | 11 VA at 415 V |
| Communication port protocol | JBUS |
| IP degree of protection | IP30 rear: conforming to IEC 60529 |
| Range | PowerLogic |
| Memory capacity | 256 kB |
| Pollution degree | 2 |
| Measurement accuracy | apparent energy +/- 0.5 % |
| Display resolution | 128 x 128 pixels |
| Market segment | buildings multi-site cost management: billing: sub feeder |
| Connections - terminals | relay output: screw terminal block4 |
| Accuracy class | class 0.5S active energy conforming to IEC 62053-22 |
| [In] rated current | 5 A |
| Depth | 72mm |
| Mounting support | framework |
| Type of measurement | active and reactive power |
| Power quality analysis | up to the 31st harmonic |
| Height | 96mm |
| Measurement current | 5-8500 mA |
| Poles description | 3P + N |
| Number of inputs | 2 digital |
| Width | 96mm |
| Operating altitude | 3000 m CAT II |
| Ride-through time | 100 ms 230 V AC typical |
| Display type | monochrome graphic LCD |
| Device short name | PM5310 |
| Compatibility code | PM5310 |
| Information displayed | tariff (4) |
| Device application | power monitoring |
| Measurement voltage | 20-440 V AC 45...65 Hz between phase and neutral |
| Standards | IEC 62052-31:2015 |
| Product certifications | cULus conforming to UL 61010-1 |
| Brand Name | Schneider Electric |
| Product name | PowerLogic PM5000 |
| Sampling rate | 64 samples/cycle |
| Net weight | 430 g |
| Product or component type | power meter |