TESYS ISLAND STARTER 25 A 11 KW
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
| Relative humidity | 5-95 % |
| Maximum operating rate | 3600 cyc/mn AC-3 |
| Electromagnetic compatibility | surge immunity test (common mode)- level 4- 4 kV- conforming to EN/IEC 61000-4-5 |
| Thermal overload class | class 5…30 |
| Ambient air temperature for operation | 50-60 °C with current derating |
| Mounting mode | horizontal and vertical (35mm symmetrical DIN rail) |
| Current consumption | 160 mA contactor closing |
| Irms rated making capacity | 450 A at 440 V conforming to IEC 60947 |
| Motor starter type | direct on line |
| [Ith] conventional free air thermal current | 30 A (at 50 °C) |
| Supplier Code | TPRST025 |
| Ambient air temperature for storage | -25-70 °C |
| Power dissipation in W | 6.6 W at Ie AC-3 |
| Reset | remotely or automatically |
| Vibration resistance | 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6 |
| [Icw] rated short-time withstand current | 240 A 40 °C - 10 s |
| Function available | power and energy monitoring when connected with TPRVM voltage module |
| Protection type | stall |
| Shock resistance | 15 gn (duration = 11 ms) conforming to IEC 60068-2-27 |
| Motor power kW | 15 kW at 500 V 50 Hz (AC-3) |
| Safety reliability level | B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| IP degree of protection | IP20 |
| Range | TeSys |
| Overvoltage category | II for Ue <= 690 V |
| Electrical durability | 2 Mcycles 30 A AC-1 at Ue 440 V |
| Device presentation | operational only when connected to a bus coupler |
| Protective treatment | TC |
| Local signalling | 1 LED (green/red) for LS (load status) |
| Pollution degree | 2 |
| Tightening torque | 2.5-2.5 N.m - with screwdriver Philips No 3 |
| Thermal protection adjustment range | 0.5-25 A |
| Metering type | number of switching cycles |
| Average impedance | 2 mOhm - Ith 30 A 50 Hz |
| [Ie] rated operational current | 30 A (at <50 °C) at <= 440 V AC-1 |
| Connections - terminals | screw-clamp terminals 2 cable(s) 1.5-10mm² (AWG 16...AWG 8) rigid |
| Depth | 115mm |
| Fire resistance | 650 °C conforming to IEC 60695-2-12 |
| Mechanical durability | 30 Mcycles |
| Height | 121mm |
| Poles description | 3P (3 NO) |
| Width | 45mm |
| Operating altitude | 0...2000 m without derating |
| Operating time | < 30 ms opening |
| [Uc] control circuit voltage | 24 V DC supplied by the bus coupler |
| Device short name | TPRST |
| Product compatibility | TPRVM voltage interface module |
| [Ue] rated operational voltage | <= 690 V AC 47...63 Hz for overvoltage cat. II |
| [Ui] rated insulation voltage | 600 V conforming to CSA C22.2 No 60947-4-1 |
| Standards | CSA C22.2 No 60947-4-1 |
| Product certifications | UL |
| Brand Name | Schneider Electric |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-1 |
| Power dissipation per pole | 1.8 W AC-1 - Ith 30 A |
| Product name | TeSys island |
| Motor power hp | 7.5 hp at 240 V AC 60 Hz for 3 phases motors |
| Utilisation category | AC-3e |
| Rated breaking capacity | 450 A at 440 V conforming to IEC 60947 |
| Net weight | 0.718 kg |
| Product or component type | motor starter |
We would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
Can't find what you're looking for?
Request now
We can source just about anything, submit a request and we'll get back to you soon.