Schneider Electric GV3P65 Motor circuit breaker,TeSys Deca frame 3,3P,48-65A,thermal magnetic,EverLink terminals, Dark Grey
Code: SCHGV3P65
Unit of measure:
EACH
Description
Motor Protection Circuit Breaker
Brand Name: Schneider
Type: Thermal Magnetic
Range: TeSys GV3
Voltage: 690 VAC
Current Type: AC
Current: 48 - 65 A
Power Rating: 55 kW
Number of Poles: 3
Break Strength: 6 kA
Frequency Rating: 50/60 Hz
Connection Type: Screw Clamp
Rotary Handle
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
Power Rating | 55 kW |
Maximum operating rate | 25 cyc/h |
Ambient air temperature for operation | -20-60 °C |
Current Type | AC |
[Ith] conventional free air thermal current | 65 A conforming to IEC 60947-4-1 |
Supplier Code | GV3P65 |
Connection Type | Screw Clamp |
Ambient air temperature for storage | -40-80 °C |
Network frequency | 50/60 Hz conforming to IEC 60947-4-1 |
Network type | AC |
Break Strength | 6 kA |
Fixing mode | panel: screwed (with 3 x M4 screws) |
Motor power kW | 45-45 kW at 500 V AC 50/60 Hz |
Magnetic tripping current | 910-910 A |
Control type | rotary handle |
IP degree of protection | IP20 conforming to IEC 60529 |
Range | TeSys Deca |
Frequency Rating | 50/60 Hz |
Electrical durability | 50000 cycles for AC-3 at 415 V In |
Item Name | Motor Protection Circuit Breaker |
Mounting position | vertical |
Tightening torque | 5 N.m - on screw clamp terminal |
Thermal protection adjustment range | 48-65 A conforming to IEC 60947-4-1 |
Current | 48 - 65A |
[Ics] rated service short-circuit breaking capacity | 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
Standard | CCC, CSA, UL Listed |
Suitability for isolation | yes conforming to IEC 60947-1 |
[In] rated current | 65 A |
Depth | 136mm |
Colour | Dark Grey |
Fire resistance | 960 °C conforming to IEC 60695-2-11 |
Mechanical durability | 50000 cycles |
Climatic withstand | conforming to IACS E10 |
Voltage | 690 VAC |
Direct connector | without |
Breaking capacity | 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
Height | 132mm |
Poles description | 3P |
Width | 55mm |
Operating altitude | 3000 m |
Device short name | GV3P |
Phase failure sensitivity | yes conforming to IEC 60947-4-1 |
Compatibility code | GV3P |
Trip unit technology | thermal-magnetic |
Mechanical robustness | vibrations: 4 Gn- 5...300 Hz |
Device application | motor protection |
[Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
[Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
Standards | IEC/EN 60335-1:Clause 30.2 |
Product certifications | UKCA |
Brand Name | Schneider Electric |
EAN/UPC | 3389119405416 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
Type | Thermal Magnetic |
Power dissipation per pole | 8 W |
Product name | TeSys GV3 |
Utilisation category | AC-3 conforming to IEC 60947-4-1 |
Rated duty | continuous conforming to IEC 60947-4-1 |
Net weight | 0.96 kg |
Number of Poles | 3 |
IK degree of protection | IK09 enclosure |
Product or component type | motor circuit breaker |
Have questions about this product?
Do you need more information? We are here to help. Click below to contact us now!
Get in touchWe would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
Can't find what you're looking for?
Request now
We can source just about anything, submit a request and we'll get back to you soon.