Schneider Electric C1634V160 Trip unit MicroLogic Vigi 4.2, ComPacT NSX160/250, 3 poles, electronic basic and earth leakage protections, 160A rating
Code: SCHC1634V160
Unit of measure:
EACH
Description
TRIP UNIT NSX160 AC 3P3D 160A 4.2
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
[Δt] residual earth-leakage time delay adjustment | 150-150 ms |
Operating mode | OFF using the IΔn rotary switch |
Long time pick-up adjustment type Ir | adjustable 9 settings |
[In] rated current | 160 A at 40 °C |
Ambient air temperature for operation | -25-70 °C |
Instantaneous pick-up adjustment type Ii | fixed |
Earth-leakage protection | integrated |
Mounting mode | fixed |
Residual earth-leakage sensitity adjustment type | adjustable |
Supplier Code | C1634V160 |
Instantaneous pick-up adjustment range | 2400 A |
Residual earth-leakage time delay adjustment type | adjustable |
Zone selective interlocking ZSI | without |
Ambient air temperature for storage | -40-85 °C |
Poles description | 3P |
Trip unit name | MicroLogic 4.2 |
Network frequency | 50/60 Hz |
[Isd] short-time pick-up adjustment range | 1.5...10 x Ir |
Short-time delay adjustment type | fixed |
Trip unit protection functions | LSoIR |
Thermal memory | 20 minutes before and after tripping |
Protected poles description | 3D |
Protection type | I : for instantaneous short-circuit protection |
Network type | AC |
Trip unit technology | electronic |
Device application | distribution |
[Ue] rated operational voltage | 440 V AC 50/60 Hz |
IP degree of protection | IP40 conforming to IEC 60529 |
Range | ComPacT new generation |
Standards | EN/IEC 60947-2 |
Long time pick-up adjustment range | 63...160 A |
Electrical shock protection class | class II |
[tr] long-time delay adjustment range | 16-16 s at 6 x Ir |
Range compatibility | ComPacT new generation NSX250 |
Local signalling | LED 90 % Ir (orange) for overload |
[IΔn] residual earth-leakage sensitive adjustment | 1-1 A |
Pollution degree | 3 conforming to IEC 60947-1 |
Long time delay adjustment type | fixed |
Short-time pick-up adjustment type Isd | adjustable |
Earth-leakage protection class | class A |
Product or component type | trip unit |
Have questions about this product?
Do you need more information? We are here to help. Click below to contact us now!
Get in touchWe would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
Can't find what you're looking for?
Request now
We can source just about anything, submit a request and we'll get back to you soon.