Schneider Electric PM5350 Monitoring system PM5350 Power & Energy meter with THD, alarming
This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 32 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to 15th Harmonic. Include a non-volatile memory for several parameters and alarms. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 85 to 265 VAC and 100 to 300 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 20V AC to 480V AC, CAT III or 20V AC to 690V AC, CAT II at 45 Hz to 70 Hz. The range of measurement voltage between Phase and Neutral is 20V AC to 277V AC, CAT III or 20V AC to 400V AC, CAT II at 45 Hz to 70 Hz. Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support. The meter also has four digital inputs and dual relay outputs. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 2.24 inches (57 millimetres), height 3.78 inches (96 millimetres) and product weight 8.8 onces (250 g).
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
Relative humidity | 5-95 % at 50-50 °C non-condensing |
[Us] rated supply voltage | 100...300 V DC |
Frequency measurement range | 45-70 Hz |
Data recording | alarms |
Electromagnetic compatibility | electrical fast transient/burst immunity test conforming to IEC 61000-4-4 |
Ambient air temperature for operation | -20-70 °C display |
Communication port support | terminal block: RS485 |
Mounting mode | flush-mounted |
Number of outputs | 2 relay |
Supplier Code | METSEPM5350 |
Type of installation | for indoor use in a stationary panel |
Ambient air temperature for storage | -40-85 °C |
Network frequency | 60 Hz |
Analogue input type | voltage (impedance 10 MOhm) |
Maximum power consumption in VA | 11.9 VA |
Communication port protocol | Modbus RTU and ASCII at 9.6- 19.2 and 38.4 kbauds |
IP degree of protection | IP54 display: conforming to IEC 60529 |
Range | PowerLogic |
Overvoltage category | III |
Item Name | Power Meter |
Pollution degree | 2 |
Measurement accuracy | apparent energy +/- 0.5 % |
Display resolution | 6 lines |
Market segment | data center cost management: cost allocation: main incomer |
Connections - terminals | input/output circuit: screw terminal block6 |
Accuracy class | class 0.5 active energy conforming to IEC 61557-12 |
[In] rated current | 1 A |
Depth | 44mm |
Type of measurement | phase angle |
Power quality analysis | total harmonic distortion |
Height | 96mm |
Measurement current | 5-9000 mA |
Poles description | 3P |
Number of inputs | 4 digital |
Width | 96mm |
Operating altitude | <= 3000 m |
Ride-through time | 400 ms 230 V AC typical |
Display type | monochrome graphic LCD |
Device short name | PM5350 |
Compatibility code | PM5350 |
Information displayed | tariff (4) |
Device application | power monitoring |
Measurement voltage | 20-277 V AC phase to neutral |
Standards | IEC 61010-1 |
Brand Name | Schneider Electric |
Product certifications | cULus |
Product name | PowerLogic PM5350 |
Sampling rate | 32 samples/cycle |
Net weight | 0.25 kg |
Product or component type | power meter |