RCBO C CURVE 1P+N 10A 30MA 6KA CL A 1M
RCBO C CURVE 1P+N 10A 30MA 6KA CL A 1M
IPD
IPD DME60DC10A30 ABB Residual Current Circuit Breaker, RCBO, 10A, 240VAC, C Curve, 1P+N, 6kA, 30mA Sensitivity, 1 Module, 125mm Height, White
Show More

IPD DME60DC10A30 ABB Residual Current Circuit Breaker, RCBO, 10A, 240VAC, C Curve, 1P+N, 6kA, 30mA Sensitivity, 1 Module, 125mm Height, White

The IPD Residual Current Circuit Breaker (RCBO) is an essential safety device designed to protect electrical circuits from overloads, short-circuit currents, and earth fault currents. With a rated current of 10A and a breaking capacity of 6kA, this circuit breaker ensures reliable operation in various applications. It features a C Curve characteristic, making it suitable for general-purpose use in residential and commercial settings.

This RCBO operates at a voltage of 240VAC and is compatible with both 50Hz and 60Hz frequency ratings. The device has a sensitivity of 30mA, providing effective protection against direct contacts. Its compact design includes a pole configuration of 1P+N and occupies just one DIN module space, measuring 125mm in height, 70mm in width, and 17.8mm in depth. Additionally, it functions effectively within a temperature range of -5 to +55°C, ensuring versatility across different environments. || The IPD Residual Current Circuit Breaker (RCBO) is an essential safety device designed to protect electrical circuits from overloads, short-circuit currents, and earth fault currents. With a rated current of 10A and a breaking capacity of 6kA, this circuit breaker ensures reliable operation in various applications. It features a C Curve characteristic, making it suitable for general-purpose use in residential and commercial settings.

This RCBO operates at a voltage of 240VAC and is compatible with both 50Hz and 60Hz frequency ratings. The device has a sensitivity of 30mA, providing effective protection against direct contacts. Its compact design includes a pole configuration of 1P+N and occupies just one DIN module space, measuring 125mm in height, 70mm in width, and 17.8mm in depth. Additionally, it functions effectively within a temperature range of -5 to +55°C, ensuring versatility across different environments.

Features:
• Rated current of 10A for reliable performance in electrical systems
• Breaking capacity of 6kA ensures effective protection against short-circuit currents
• C Curve characteristic for optimal response to overload conditions
• Pole configuration of 1P+N for versatile installation options
• Compact dimensions with a height of 125mm, width of 70mm, and length of 17.8mm
• Designed for a frequency rating of 50/60Hz for compatibility with various electrical systems
• Temperature range of -5 to 55°C for reliable operation in diverse environments
• Sensitivity of 30mA for effective protection against earth fault currents
• Single din module design for easy installation in standard electrical panels