IPD DME60DC20A30 ABB Residual Current Circuit Breaker, 1P+N, 20A, 6kA Breaking Capacity, C Curve, 1 Module, Long Body, 240VAC, 30mA, 50/60Hz, White
The IPD Residual Current Circuit Breaker (RCBO) is an essential safety device designed to protect electrical circuits from overloads, short-circuit currents, and earth fault currents. With a rated current of 20A and a breaking capacity of 6kA, this circuit breaker ensures reliable operation in various applications. The device features a C Curve characteristic, making it suitable for protecting circuits with moderate inrush currents, while its pole configuration of 1P+N allows for effective protection of both live and neutral conductors.
This RCBO operates within a frequency rating of 50/60Hz and is designed to function effectively within a temperature range of -5 to 55°C. Measuring 17.8mm in length, 70mm in width, and 125mm in height, it occupies just one DIN module space for easy installation in standard distribution boards. Additionally, the neutral is unswitched, ensuring continuous operation while providing protection against direct contacts with its 30mA version. || The IPD Residual Current Circuit Breaker (RCBO) is an essential safety device designed to protect electrical circuits from overloads, short-circuit currents, and earth fault currents. With a rated current of 20A and a breaking capacity of 6kA, this circuit breaker ensures reliable operation in various applications. The device features a C Curve characteristic, making it suitable for protecting circuits with moderate inrush currents, while its pole configuration of 1P+N allows for effective protection of both live and neutral conductors.
This RCBO operates within a frequency rating of 50/60Hz and is designed to function effectively within a temperature range of -5 to 55°C. Measuring 17.8mm in length, 70mm in width, and 125mm in height, it occupies just one DIN module space for easy installation in standard distribution boards. Additionally, the neutral is unswitched, ensuring continuous operation while providing protection against direct contacts with its 30mA version.
Features:
• Rated current of 20A for reliable performance
• Breaking capacity of 6kA for effective fault protection
• C Curve characteristic for optimal tripping in overload conditions
• Pole configuration of 1P+N for versatile installation options
• Designed for a temperature range of -5 to 55°C for diverse environments
• Frequency rating of 50/60Hz for compatibility with standard electrical systems
• Compact dimensions with a length of 17.8mm, width of 70mm, and height of 125mm
• Protection against short-circuit currents, overload, and earth fault currents
• Neutral is unswitched for enhanced safety during maintenance