Schneider Electric ATV12HU22M2 Variable speed drive ATV12, Altivar 12, 2.2kW, 3hp, 200..240V, 1ph, with heat sink
Code: SCHATV12HU22M2
Unit of measure:
EACH
Description
ATV12 2.2KW 240V 1PH HEAT SINK TB
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
With safety function Safe brake management (SBC/SBT) | false |
Relative humidity | 5-95 % without dripping water conforming to IEC 60068-2-3 |
Data format | 8 bits- configurable odd- even or no parity |
With safety function Safe Speed Monitor (SSM) | false |
Maximum deflection under vibratory load (during operation) | 1.5mm at 2...13 Hz |
Line current | 20.2 A at 120 V (heavy duty) |
Environmental class (during storage) | class 1S2 according to IEC 60721-3-1 |
Supporting protocol for Data-Highway | false |
Operating element present | true |
Ambient air temperature for operation | 50-60 °C with current derating 2.2 % per °C |
Connector type | 1 RJ45 |
Switching frequency | 4...16 kHz with derating factor |
Supporting protocol for EtherNet/IP | false |
Speed range | 1-20 |
Ambient air temperature for storage | -25-70 °C |
Number of input phases | 3 |
Number of addresses | 1-247 |
Apparent power | 4.8 kVA at 240 V (heavy duty) |
Frequency resolution | display unit: 0.1 Hz |
Power dissipation in W | forced cooling: 93.0 W |
Sampling duration | 10 ms for analogue input |
Brake chopper integrated | false |
Discrete input number | 4 |
Protection type | thermal motor protection via the drive by continuous calculation of I²t |
Relative symmetric mains voltage tolerance | 10 % |
Motor power kW | 2.2 kW |
Supporting protocol for DeviceNet | false |
Quantity per set | set of 1 |
With safety function Safely Limited Position (SLP) | false |
Supporting protocol for INTERBUS-Safety | false |
Supporting protocol for Foundation Fieldbus | false |
Supporting protocol for PROFINET IO | false |
Application in domestic and commercial area permitted | false |
Computer port | true |
Maximum input current | 20.2 A |
4 quadrant operation possible | false |
Pollution degree | 2 |
Prospective line Isc | 1 kA |
Number of HW interfaces serial RS232 | 0 |
With sft fct Safe Stop 2 (SS2) | false |
Supporting protocol for TCP/IP | false |
With safety function Safely Limited Speed (SLS) | false |
Number of HW interfaces serial TTY | 0 |
Product specific application | simple machine |
With safety function Safe torque off (STO) | false |
Depth | 156.2mm |
Supporting protocol for INTERBUS | false |
Design of frequency changer | U converter |
Application in industrial area permitted | true |
Volume of cooling air | 16 m3/h |
Supporting protocol for LON | false |
Linearity error | +/- 0.3 % of maximum value for analogue input |
Housing material | plastic |
Number of output phases | 3 |
Maximum deflection under vibratory load (during transport) | 1.5mm at 2...13 Hz |
Width | 105mm |
Supporting protocol for SafetyBUS P | false |
Operating altitude | <= 1000 m without derating |
Capacity of DC link | 1890.0 µF |
Ambient air transport temperature | -25-70 °C |
Nominal output current | 10 A |
Maximum acceleration under vibratory load (during storage) | 10 m/s² at 13...200 Hz |
Power loss static current independent | 11.0 W |
Method of access | server Modbus serial |
Maximum output voltage | 240 V |
Relay output number | 1 |
Analogue output number | 1 |
Supporting protocol for BACnet | false |
Number of HW interfaces parallel | 0 |
Transmission frame | RTU |
Motor slip compensation | preset in factory |
Analogue input number | 1 |
Supply frequency | 50/60 Hz +/- 5 % |
Environmental class (during operation) | class 3S2 according to IEC 60721-3-3 |
Number of inputs- potential-free | 0 |
Net weight | 1.4 kg |
Transmission rate | 19.2 kbit/s |
Asynchronous motor control profile | voltage/frequency ratio (V/f) |
Supporting protocol for DeviceNet Safety | false |
Supporting protocol for SUCONET | false |
[Us] rated supply voltage | 200...240 V - 15...10 % |
EMC filter | integrated |
With safety function Safe Stop 1 (SS1) | false |
Operating position | vertical +/- 10 degree |
Supporting protocol for ASI | false |
Electromagnetic compatibility | voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
Maximum transient current | 16.5 A during 2 s (heavy duty) |
Nominal switching frequency | 4 kHz |
Supporting protocol for KNX | false |
With safety function Safe Direction (SDI) | false |
Environmental class (during transport) | class 2S1 according to IEC 60721-3-2 |
Noise level | 45 dB |
Number of HW interfaces USB | 0 |
Relative symmetric network frequency tolerance | 5 % |
Mounting mode | cabinet mount |
Supplier Code | ATV12HU22M2 |
Number of HW interfaces serial RS422 | 0 |
Supporting protocol for SERCOS | false |
Network frequency | 50...60 Hz |
Type of polarization | no impedance |
Time constant | 20 ms +/- 1 ms for reference change |
Vibration resistance | 1.5mm peak to peak (f = 3-13 Hz) - drive unmounted on symmetrical DIN rail - conforming to IEC 60068-2-6 |
With safety function Safe Operating Stop (SOS) | false |
Insulation | electrical between power and control |
Supporting protocol for other bus systems | false |
With safety function Safe Position (SP) | false |
Shock resistance | 15 gn conforming to IEC 60068-2-27 for 11 ms |
Maximum acceleration under shock load (during transport) | 150 m/s² at 11 ms |
Communication port protocol | Modbus |
IP degree of protection | IP20 |
Range | Altivar 12 |
Overvoltage category | class III |
Optical interface present | false |
Number of inputs- bidirectional- not potential-free | 0 |
Assembly style | with heat sink |
EMC limit value (complied) | true |
Tightening torque | 1.2 N.m |
1 phase low current possible | false |
Acceleration and deceleration ramps | S |
Nominal output power | 2200.0 W |
Communication service | read/write multiple registers (23) 4/4 words |
Maximum acceleration under vibratory load (during transport) | 10 m/s² at 13...200 Hz |
Base load current at high overload | 10.0 A |
Supporting protocol for CAN | false |
Power loss per device current dependent | 93.0 W |
Supporting protocol for PROFINET CBA | false |
Height | 142mm |
Electromagnetic emission | conducted emissions with additional EMC filter environment 1 category C1 conforming to IEC 61800-3 4...12 kHz shielded motor cable <20 m |
Number of HW interfaces serial RS485 | 1 |
Supporting protocol for PROFIBUS | false |
Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
Continuous output current | 10 A at 4 kHz |
Number of HW interfaces PROFINET | 0 |
Regulation loop | adjustable PID regulator |
Maximum output frequency | 4 kHz |
Number of HW interfaces other | 0 |
Discrete output number | 2 |
Maximum associated fuse rating | 12.5 A |
Marking | CE |
Maximum deflection under vibratory load (during storage) | 1.5mm at 2...13 Hz |
Supporting protocol for PROFIsafe | false |
Standards | IEC 61800-5-1 |
Product certifications | UL |
With safety function Safe programmable logic | false |
Braking to standstill | by DC injection |
Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
Supporting protocol for AS-Interface Safety at Work | false |
Motor power hp | 3 hp |
Number of HW interfaces industrial Ethernet | 0 |
Supporting protocol for MODBUS | true |
Transient overtorque | 150-170 % of nominal motor torque depending on drive rating and type of motor |
Physical interface | 2-wire RS 485 |
Speed drive output frequency | 0.5-400 Hz |
Maximum acceleration under shock load (during storage) | 150 m/s² at 11 ms |
Product or component type | variable speed drive |
Have questions about this product?
Do you need more information? We are here to help. Click below to contact us now!
Get in touchWe would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
Can't find what you're looking for?
Request now
We can source just about anything, submit a request and we'll get back to you soon.