Schneider Electric ATS480D38Y Soft starter, Altistart 480, 38A, 208 to 690V AC, control supply 110 to 230V AC
Code: SCHATS480D38Y
Unit of measure:
EACH
Description
SOFT STARTER ATS480 38A 208 TO 690V
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
Product destination | asynchronous motors |
With safety function Safe brake management (SBC/SBT) | false |
Relative humidity | 0-95 % without condensation or dripping water conforming to IEC 60068-2-3 |
Data format | 8 bits- configurable odd- even or no parity |
[Us] rated supply voltage | 208...690 V - 15...10 % |
With safety function Safe Speed Monitor (SSM) | false |
Maximum deflection under vibratory load (during operation) | 1.5mm at 2...13 Hz |
With safety function Safe Stop 1 (SS1) | false |
Operating position | vertical +/- 10 degree |
Electromagnetic compatibility | immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 |
Ambient air temperature for operation | -15-40 °C (without derating) |
Connector type | 1 RJ45 |
With safety function Safe Direction (SDI) | false |
Noise level | 52.0 dB |
Minimum switching current | 100 mA at 12 V DC for relay outputs |
Analogue output type | current output AQ1: 0...20 mA or 0...10 V- impedance <500 Ohm |
Supplier Code | ATS480D38Y |
Ambient air temperature for storage | -25-70 °C |
Number of addresses | 0-227 for Modbus serial |
Discrete output type | (DQ2) programmable digital output <= 30 V |
Apparent power | 0.09 kVA |
Network frequency | 50/60 Hz |
Type of polarization | no impedance for Modbus serial |
Communication data link | serial |
With safety function Safe Operating Stop (SOS) | false |
Discrete input number | 4 |
Network number of phases | 3 phases |
With safety function Safe Position (SP) | false |
Function available | cybersecure firmware update |
Analogue input type | PTC3 PTC/Pt 100 temperature probe |
Protection type | thermal protection: starter |
Maximum acceleration under shock load (during transport) | 100 m/s² at 11 ms |
Motor power kW | 15.0 kW at 400 V in the motor supply line heavy duty |
Device connection | to the motor delta terminals |
Communication port protocol | Modbus serial |
With safety function Safely Limited Position (SLP) | false |
IP degree of protection | IP20 |
Range | Altivar Soft Starter ATS480 |
Display screen available | true |
Option card | communication module for Modbus TCP/EtherNet/IP |
Pollution degree | level 3 |
With sft fct Safe Stop 2 (SS2) | false |
[Ie] rated operational current | normal duty: 38.0 A (at <40 °C) |
With safety function Safely Limited Speed (SLS) | false |
Maximum acceleration under vibratory load (during transport) | 10 m/s² at 9...200 Hz |
Product specific application | process and infrastructures |
Input compatibility | DI4: discrete input level 1 PLC conforming to IEC 61131-2 |
Accuracy class | class 10E |
Discrete input logic | programmable digital input at State 0: < 5 V |
With safety function Safe torque off (STO) | false |
Depth | 203.0mm |
Volume of cooling air | 14.0 m3/h |
Power loss per device current dependent | 96.0 W |
Maximum permanent current | 32.0 A at 40 °C for heavy duty |
Suitable for mounting onto standard rails | false |
Maximum switching current | |
Integrated motor overload protection | true |
Height | 275.0mm |
Output current drift | 150-700 % |
Maximum deflection under vibratory load (during transport) | 1.75mm at 2...9 Hz |
Relay output type | relay outputs R1B 1 NO |
Width | 160.0mm |
Operating altitude | > 1000...4000 m with current derating 1 % per 100 m |
Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
[Uc] control circuit voltage | 110...230 V AC 50/60 Hz - 15...10 % |
Device short name | ATS480 |
Maximum acceleration under vibratory load (during storage) | 10 m/s² at 9...200 Hz |
Rated current pwr loss specification | 38.0 A |
Power loss static current independent | 25.0 W |
Method of access | slave Modbus serial |
Discrete output number | 2 |
Output compatibility | open collector level 1 PLC conforming to IEC 65A-68 |
Relay output number | 3 |
Analogue output number | 1 |
[Ui] rated insulation voltage | 690 V |
Marking | cULus |
Maximum deflection under vibratory load (during storage) | 1.75mm at 2...9 Hz |
Standards | IEC 60664-1 |
Product certifications | CCC |
Transmission frame | RTU |
With safety function Safe programmable logic | false |
Analogue input number | 1 |
Supply frequency | 50...60 Hz - 20...20 % |
Environmental class (during operation) | class 3S2 according to IEC 60721-3-3 |
[Uimp] rated impulse withstand voltage | 6 kV |
Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
Motor power hp | 25.0 hp at 575 V heavy duty |
Torque control | true |
Utilisation category | AC-53A |
Discrete input type | (DI4) programmable as logic input- 3500 Ohm |
Net weight | 4.9 kg |
Transmission rate | 1200...256000 bit/s |
Physical interface | 2-wire RS 485 |
Maximum acceleration under shock load (during storage) | 100 m/s² at 11 ms |
Product or component type | soft starter |
Have questions about this product?
Do you need more information? We are here to help. Click below to contact us now!
Get in touchWe would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
Can't find what you're looking for?
Request now
We can source just about anything, submit a request and we'll get back to you soon.