VARIABLE SPEED DRIVE IP21 11KW 400V/480V
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
Product destination | asynchronous motors |
With safety function Safe brake management (SBC/SBT) | false |
Relative humidity | 5-95 % without condensation conforming to IEC 60068-2-3 |
Data format | 8 bits- configurable odd- even or no parity |
With safety function Safe Speed Monitor (SSM) | false |
Maximum deflection under vibratory load (during operation) | 1.5mm at 2...13 Hz |
Line current | 14.1 A at 380 V (heavy duty) |
Environmental class (during storage) | class 1S2 according to EN 60721-3-1 |
Supporting protocol for Data-Highway | false |
Operating element present | true |
Ambient air temperature for operation | 50-60 °C (with derating factor) |
Connector type | RJ45 (on the remote graphic terminal) for Modbus serial |
Minimum switching current | relay output R1- R2- R3: 5 mA at 24 V DC |
Electrical connection | motor: screw terminal 6...10mm²/AWG 10...AWG 8 |
Supporting protocol for EtherNet/IP | true |
Switching frequency | 4...12 kHz with derating factor |
Analogue output type | software-configurable current DQ-- DQ+: 100 mA |
Motor starter type | variable speed drive |
Output voltage | <= power supply voltage |
Ambient air temperature for storage | -40-70 °C |
Number of input phases | 3 |
Number of addresses | 1-247 for Modbus serial |
Discrete output type | relay outputs R2A- R2C 250 V AC 5000 mA |
Apparent power | 10.4 kVA at 480 V (heavy duty) |
Frequency resolution | analog input: 0.012/50 Hz |
Power dissipation in W | forced convection: 255 W at 380 V- switching frequency 4 kHz |
Exchange mode | half duplex- full duplex- autonegotiation Ethernet/Modbus TCP |
Sampling duration | 10 ms +/- 1 ms (AO1) - analog output |
Brake chopper integrated | false |
Discrete input number | 8 |
Protection type | short-circuit protection: drive |
Relative symmetric mains voltage tolerance | 10 % |
Motor power kW | 7.5 kW (heavy duty) |
Supporting protocol for DeviceNet | false |
Quantity per set | 1 |
With safety function Safely Limited Position (SLP) | false |
Permissible temporary current boost | 1.5 x In during 60 s (heavy duty) |
Supporting protocol for INTERBUS-Safety | false |
Supporting protocol for Foundation Fieldbus | false |
Supporting protocol for PROFINET IO | true |
Variant | standard version |
Application in domestic and commercial area permitted | false |
Computer port | true |
Maximum input current | 19.8 A |
4 quadrant operation possible | false |
Local signalling | 4 LEDs (dual colour) for communication module status |
Option card | slot A: communication module- PROFINET |
Pollution degree | 2 conforming to IEC 61800-5-1 |
Prospective line Isc | 50 kA |
Number of HW interfaces serial RS232 | 0 |
With sft fct Safe Stop 2 (SS2) | false |
Supporting protocol for TCP/IP | true |
Permitted relative humidity (during transport) | class 2K5 according to EN 60721-3 |
With safety function Safely Limited Speed (SLS) | false |
Number of HW interfaces serial TTY | 0 |
Discrete and process manufacturing | food and beverage processing fan |
Supply | internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %- <10 mA- protection type: overload and short-circuit protection |
Input compatibility | DI5- DI6: discrete input level 1 PLC conforming to IEC 65A-68 |
Product specific application | process and utilities |
Enclosure mounting | wall mounted |
Discrete input logic | negative logic (sink) (DI1...DI8)- > 16 V (state 0)- < 10 V (state 1) |
With safety function Safe torque off (STO) | true |
Depth | 233mm |
Application in industrial area permitted | true |
Supporting protocol for INTERBUS | false |
Design of frequency changer | U converter |
Volume of cooling air | 103 m3/h |
Supporting protocol for LON | false |
Linearity error | AO1- AO2: +/- 0.2 % for analog output |
Housing material | plastic |
Number of output phases | 3 |
Maximum deflection under vibratory load (during transport) | 1.5mm at 2...13 Hz |
Width | 171mm |
Supporting protocol for SafetyBUS P | false |
Ambient air transport temperature | -40-70 °C |
Operating altitude | 1000...4800 m with current derating 1 % per 100 m |
Capacity of DC link | 1000.0 µF |
Nominal output current | 23.5 A |
Device short name | ATV630 |
NEMA degree of protection | NEMA 1 |
Power loss static current independent | 17.0 W |
Maximum acceleration under vibratory load (during storage) | 10 m/s² at 13...200 Hz |
Method of access | slave Modbus TCP |
Permitted relative humidity (during operation) | class 3K5 according to EN 60721-3 |
Maximum output voltage | 480.0 V |
Analogue output number | 2 |
Relay output number | 3 |
Supporting protocol for BACnet | false |
Number of HW interfaces parallel | 0 |
Transmission frame | RTU |
Motor slip compensation | can be suppressed |
Supply frequency | 50...60 Hz - 5...5 % |
Environmental class (during operation) | class 3S3 according to IEC 60721-3-3 |
Analogue input number | 3 |
Number of inputs- potential-free | 0 |
Discrete input type | DI7- DI8 programmable as pulse input: 0-30 kHz- 24 V DC (<= 30 V) |
Transmission rate | 4800 bps- 9600 bps- 19200 bps- 38.4 Kbps |
Net weight | 7.7 kg |
Specific application | utility |
Synchronous motor control profile | synchronous reluctance motor |
Refresh time | relay output (R1- R2- R3): 5 ms (+/- 0.5 ms) |
Asynchronous motor control profile | optimized torque mode |
Supporting protocol for DeviceNet Safety | false |
Supporting protocol for SUCONET | false |
Maximum THDI | <48 % from 80...100 % of load conforming to IEC 61000-3-12 |
EMC filter | integrated with 150 m conforming to IEC 61800-3 category C3 |
[Us] rated supply voltage | 380...480 V - 15...10 % |
With safety function Safe Stop 1 (SS1) | false |
Operating position | vertical +/- 10 degree |
Supporting protocol for ASI | false |
Electromagnetic compatibility | radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 |
Maximum transient current | 24.8 A during 60 s (heavy duty) |
Permitted relative humidity (during storage) | class 1K5 according to EN 60721-3 |
Nominal switching frequency | 4 kHz |
Supporting protocol for KNX | false |
Noise level | 56 dB |
Environmental class (during transport) | class 2S1 according to EN 60721-3-2 |
Base load current at low overload | 23.5 A |
With safety function Safe Direction (SDI) | false |
Number of HW interfaces USB | 0 |
Relative symmetric network frequency tolerance | 5 % |
Mounting mode | wall mount |
Supplier Code | ATV630D11N4 |
Number of HW interfaces serial RS422 | 0 |
Supporting protocol for SERCOS | false |
Network frequency | 50...60 Hz |
Type of polarization | no impedance |
Vibration resistance | 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6 |
With safety function Safe Operating Stop (SOS) | false |
Supporting protocol for other bus systems | false |
Network number of phases | 3 phases |
With safety function Safe Position (SP) | false |
Analogue input type | AI1- AI2- AI3 software-configurable current: 0...20 mA- impedance: 250 Ohm- resolution 12 bits |
Shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
Maximum acceleration under shock load (during transport) | 150 m/s² at 11 ms |
Insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth |
Communication port protocol | Ethernet |
Degree of protection | UL type 1 conforming to UL 508C |
IP degree of protection | IP21 |
Range | Altivar Process ATV600 |
Overvoltage category | III |
Optical interface present | false |
Number of inputs- bidirectional- not potential-free | 0 |
EMC limit value (complied) | true |
1 phase low current possible | false |
Acceleration and deceleration ramps | linear adjustable separately from 0.01...9999 s |
Nominal output power | 11.0 kW |
Maximum acceleration under vibratory load (during transport) | 10 m/s² at 13...200 Hz |
Power range | 7-11 kW at 480-500 V 3 phases |
Base load current at high overload | 16.5 A |
Accuracy | +/- 1 % AO1- AO2 for a temperature variation 60 °C analog output |
Supporting protocol for CAN | true |
Power loss per device current dependent | 349.0 W |
Supporting protocol for PROFINET CBA | true |
Maximum switching current | relay output R1- R2- R3 on resistive load- cos phi = 1 : 3 A at 30 V DC |
Height | 409mm |
Number of HW interfaces serial RS485 | 1 |
Relay output type | configurable relay logic R3: sequence relay NO electrical durability 100000 cycles |
Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
Supporting protocol for PROFIBUS | true |
Continuous output current | 16.5 A at 4 kHz for heavy duty |
Number of HW interfaces PROFINET | 0 |
Type of cooling | forced convection |
Regulation loop | adjustable PID regulator |
Maximum output frequency | 500 kHz |
Number of HW interfaces other | 0 |
Discrete output number | 0 |
Maximum associated fuse rating | 40.0 A |
Safety function | STO (safe torque off) SIL 3 |
Marking | CE |
Maximum deflection under vibratory load (during storage) | 1.5mm at 2...13 Hz |
Supporting protocol for PROFIsafe | false |
Standards | environment 2 category C3 IEC 61800-3 |
With safety function Safe programmable logic | false |
Product certifications | CSA |
Brand Name | Schneider Electric |
Braking to standstill | by DC injection |
Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
Supporting protocol for AS-Interface Safety at Work | false |
Motor power hp | 10 hp heavy duty |
Number of HW interfaces industrial Ethernet | 1 |
Isolation | between power and control terminals |
Supporting protocol for MODBUS | true |
Physical interface | 2-wire RS 485 |
Speed drive output frequency | 0.1-500 Hz |
Maximum acceleration under shock load (during storage) | 150 m/s² at 11 ms |