Schneider Electric ATV630D37N4 variable speed drive, Altivar Process ATV600, ATV630, 37kW, 50hp, 380 to 480V, IP21, UL type 1
Code: SCHATV630D37N4
Unit of measure:
EACH
Description
Schneider ATV630D37N4 Altivar Process ATV600/630 Series Variable Speed Drive, VSD, 37kw (50hp), 415V, 57.3A Normal Duty, Three Phase, IP21, 226mm x 673mm x 271mm
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
With safety function Safe brake management (SBC/SBT) | false |
Relative humidity | 5-95 % without condensation conforming to IEC 60068-2-3 |
Data format | 8 bits- configurable odd- even or no parity |
Maximum deflection under vibratory load (during operation) | 1.5mm at 2...13 Hz |
Environmental class (during storage) | class 1S2 according to EN 60721-3-1 |
Supporting protocol for Data-Highway | false |
Ambient air temperature for operation | 50-60 °C (with derating factor) |
Number of addresses | 1-247 for Modbus serial |
Frequency resolution | analog input: 0.012/50 Hz |
Sampling duration | 5 ms +/- 0.1 ms (AI1- AI2- AI3) - analog input |
Brake chopper integrated | false |
Supporting protocol for DeviceNet | false |
Supporting protocol for Foundation Fieldbus | false |
Computer port | true |
Local signalling | 1 LED (red) for presence of voltage |
With safety function Safely Limited Speed (SLS) | false |
Number of HW interfaces serial TTY | 0 |
Discrete and process manufacturing | oil and gas water injection pump |
Input compatibility | STOA- STOB: discrete input level 1 PLC conforming to IEC 61131-2 |
Product specific application | process and utilities |
Enclosure mounting | wall mounted |
Supporting protocol for INTERBUS | false |
Volume of cooling air | 240 m3/h |
Housing material | plastic |
Supporting protocol for SafetyBUS P | false |
Capacity of DC link | 2500.0 µF |
Nominal output current | 74.5 A |
Maximum acceleration under vibratory load (during storage) | 10 m/s² at 13...200 Hz |
Permitted relative humidity (during operation) | class 3K5 according to EN 60721-3 |
Maximum output voltage | 480.0 V |
Relay output number | 3 |
Number of HW interfaces parallel | 0 |
Transmission frame | RTU |
Motor slip compensation | can be suppressed |
Supply frequency | 50...60 Hz - 5...5 % |
Discrete input type | DI7- DI8 programmable as pulse input: 0-30 kHz- 24 V DC (<= 30 V) |
Synchronous motor control profile | synchronous reluctance motor |
Refresh time | relay output (R1- R2- R3): 5 ms (+/- 0.5 ms) |
Supporting protocol for DeviceNet Safety | false |
[Us] rated supply voltage | 380...480 V - 15...10 % |
Supporting protocol for ASI | false |
Electromagnetic compatibility | conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
Maximum transient current | 82 A during 60 s (normal duty) |
Nominal switching frequency | 4 kHz |
Number of HW interfaces USB | 0 |
Relative symmetric network frequency tolerance | 5 % |
Mounting mode | wall mount |
Number of HW interfaces serial RS422 | 0 |
Supporting protocol for SERCOS | false |
Type of polarization | no impedance |
Shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
Insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth |
Communication port protocol | Modbus serial |
Weight | 28.2kg |
EMC limit value (complied) | true |
Maximum acceleration under vibratory load (during transport) | 10 m/s² at 13...200 Hz |
Power range | 30-50 kW at 480-500 V 3 phases |
Standard | UL 508C, EN/IEC 61800-3, environment 1 category C2 EN/IEC 61800-3, environment 2 category C3 EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508 and IEC 13849-1 |
Power loss per device current dependent | 1030.0 W |
Supporting protocol for PROFINET CBA | true |
Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
Continuous output current | 61.5 A at 4 kHz for heavy duty |
Regulation loop | adjustable PID regulator |
Maximum associated fuse rating | 125.0 A |
Safety function | STO (safe torque off) SIL 3 |
Marking | CE |
Maximum deflection under vibratory load (during storage) | 1.5mm at 2...13 Hz |
Product certifications | UL |
Brand Name | Schneider Electric |
Braking to standstill | by DC injection |
Supporting protocol for AS-Interface Safety at Work | false |
IP Rating | IP21 |
Product destination | synchronous motors |
With safety function Safe Speed Monitor (SSM) | false |
Line current | 54.8 A at 380 V (heavy duty) |
Operating element present | true |
Connector type | RJ45 (on the remote graphic terminal) for Modbus serial |
Minimum switching current | relay output R1- R2- R3: 5 mA at 24 V DC |
Electrical connection | line side: screw terminal 35...50mm²/AWG 3...AWG 1 |
Supporting protocol for EtherNet/IP | true |
Switching frequency | 4...12 kHz with derating factor |
Analogue output type | software-configurable current DQ-- DQ+: 100 mA |
Motor starter type | variable speed drive |
Output voltage | <= power supply voltage |
Ambient air temperature for storage | -40-70 °C |
Number of input phases | 3 |
Discrete output type | relay outputs R2A- R2C 250 V AC 5000 mA |
Apparent power | 40.2 kVA at 480 V (heavy duty) |
Power dissipation in W | forced convection: 796 W at 380 V- switching frequency 4 kHz |
Exchange mode | half duplex- full duplex- autonegotiation Ethernet/Modbus TCP |
Discrete input number | 8 |
Protection type | motor phase break: motor |
Relative symmetric mains voltage tolerance | 10 % |
Motor power kW | 30 kW (heavy duty) |
Quantity per set | 1 |
With safety function Safely Limited Position (SLP) | false |
Permissible temporary current boost | 1.5 x In during 60 s (heavy duty) |
Supporting protocol for INTERBUS-Safety | false |
Supporting protocol for PROFINET IO | true |
Variant | standard version |
Noise Level | 63.5 dB |
Application in domestic and commercial area permitted | false |
Item Name | Variable Speed Drive |
Maximum input current | 66.2 A |
4 quadrant operation possible | false |
Option card | slot A: communication module- DeviceNet |
Pollution degree | 2 conforming to IEC 61800-5-1 |
Prospective line Isc | 50 kA |
Number of HW interfaces serial RS232 | 0 |
With sft fct Safe Stop 2 (SS2) | false |
Supporting protocol for TCP/IP | true |
Permitted relative humidity (during transport) | class 2K5 according to EN 60721-3 |
Supply | internal supply for digital inputs and STO: 24 V DC (21-27 V)- <200 mA- protection type: overload and short-circuit protection |
Discrete input logic | negative logic (sink) (DI1...DI8)- > 16 V (state 0)- < 10 V (state 1) |
With safety function Safe torque off (STO) | true |
Depth | 271mm |
Application in industrial area permitted | true |
Design of frequency changer | U converter |
Supporting protocol for LON | false |
Linearity error | AO1- AO2: +/- 0.2 % for analog output |
Number of output phases | 3 |
Maximum deflection under vibratory load (during transport) | 1.5mm at 2...13 Hz |
Width | 226mm |
Ambient air transport temperature | -40-70 °C |
Operating altitude | 1000...4800 m with current derating 1 % per 100 m |
Device short name | ATV630 |
NEMA degree of protection | NEMA 1 |
Power loss static current independent | 31.0 W |
Method of access | slave Modbus TCP |
Analogue output number | 2 |
Supporting protocol for BACnet | false |
Environmental class (during operation) | class 3S3 according to IEC 60721-3-3 |
Analogue input number | 3 |
Number of inputs- potential-free | 0 |
Transmission rate | 4800 bps- 9600 bps- 19200 bps- 38.4 Kbps |
Net weight | 28.2 kg |
Specific application | utility |
Asynchronous motor control profile | constant torque standard |
Supporting protocol for SUCONET | false |
Maximum THDI | <48 % from 80...100 % of load conforming to IEC 61000-3-12 |
EMC filter | integrated with 150 m conforming to IEC 61800-3 category C3 |
With safety function Safe Stop 1 (SS1) | false |
Operating position | vertical +/- 10 degree |
Wattage | 37kW |
Permitted relative humidity (during storage) | class 1K5 according to EN 60721-3 |
Supporting protocol for KNX | false |
Environmental class (during transport) | class 2S1 according to EN 60721-3-2 |
Base load current at low overload | 74.5 A |
With safety function Safe Direction (SDI) | false |
Supplier Code | ATV630D37N4 |
Connection Type | RJ45 |
Network frequency | 50...60 Hz |
Vibration resistance | 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6 |
With safety function Safe Operating Stop (SOS) | false |
Supporting protocol for other bus systems | false |
Network number of phases | 3 phases |
With safety function Safe Position (SP) | false |
Analogue input type | AI2 voltage analog input: - 10...10 V DC- impedance: 31.5 kOhm- resolution 12 bits |
Maximum acceleration under shock load (during transport) | 150 m/s² at 11 ms |
Degree of protection | UL type 1 conforming to UL 508C |
IP degree of protection | IP21 |
Range | Altivar Process ATV600 |
Overvoltage category | III |
Optical interface present | false |
Number of inputs- bidirectional- not potential-free | 0 |
Functionality | full |
1 phase low current possible | false |
Acceleration and deceleration ramps | linear adjustable separately from 0.01...9999 s |
Nominal output power | 37.0 kW |
Phase | 3 Phase |
Base load current at high overload | 61.5 A |
Accuracy | +/- 1 % AO1- AO2 for a temperature variation 60 °C analog output |
Supporting protocol for CAN | true |
Voltage | 380 - 480V AC |
Maximum switching current | relay output R1- R2- R3 on inductive load- cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
Height | 673mm |
Number of HW interfaces serial RS485 | 1 |
Relay output type | configurable relay logic R2: sequence relay NO electrical durability 100000 cycles |
Supporting protocol for PROFIBUS | true |
Number of HW interfaces PROFINET | 0 |
Type of cooling | forced convection |
Maximum output frequency | 500 kHz |
Number of HW interfaces other | 0 |
Discrete output number | 0 |
Supporting protocol for PROFIsafe | false |
Standards | IEC 61508 |
With safety function Safe programmable logic | false |
Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
Motor power hp | 40 hp heavy duty |
Number of HW interfaces industrial Ethernet | 1 |
Isolation | between power and control terminals |
Supporting protocol for MODBUS | true |
Physical interface | 2-wire RS 485 |
Speed drive output frequency | 0.1-500 Hz |
Maximum acceleration under shock load (during storage) | 150 m/s² at 11 ms |
Product or component type | variable speed drive |
Downloads
Have questions about this product?
Do you need more information? We are here to help. Click below to contact us now!
Get in touchWe would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
Can't find what you're looking for?
Request now
We can source just about anything, submit a request and we'll get back to you soon.