Schneider Electric ATV320U40N4B variable speed drive, Altivar Machine ATV320, 4kW, 380 to 500V, 3 phases, book
Code: SCHATV320U40N4B
Unit of measure:
EACH
Description
ATV320 4KW 400V 3PH BOOK CONTROL VARIABL
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
With safety function Safe brake management (SBC/SBT) | false |
With safety function Safe Speed Monitor (SSM) | false |
Maximum deflection under vibratory load (during operation) | 1.5mm at 2...13 Hz |
Line current | 10.5 A at 500 V (heavy duty) |
Environmental class (during storage) | class 1S2 according to EN 60721-3 |
Supporting protocol for Data-Highway | false |
Operating element present | true |
Ambient air temperature for operation | -10-50 °C without derating |
Minimum switching current | relay output R1A- R1B- R1C- R2A- R2C: 5 mA at 24 V DC |
Supporting protocol for EtherNet/IP | true |
Switching frequency | 4...16 kHz with derating factor |
Analogue output type | software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm- resolution 10 bits |
Ambient air temperature for storage | -25-70 °C |
Number of input phases | 3 |
Discrete output type | open collector DQ- 0-1 kHz 30 V DC 100 mA |
Apparent power | 9.1 kVA at 500 V (heavy duty) |
Power dissipation in W | fan: 111 W at 380 V- switching frequency 4 kHz |
Sampling duration | 2 ms (AQ1) - analog output |
Brake chopper integrated | true |
Discrete input number | 7 |
Protection type | overcurrent between output phases and earth: drive |
Encoder protocol | RS 422 |
Relative symmetric mains voltage tolerance | 10 % |
Motor power kW | 4.0 kW for heavy duty |
Supporting protocol for DeviceNet | true |
With safety function Safely Limited Position (SLP) | false |
Supporting protocol for INTERBUS-Safety | false |
Supporting protocol for Foundation Fieldbus | false |
Supporting protocol for PROFINET IO | true |
Variant | standard version |
Application in domestic and commercial area permitted | false |
Computer port | true |
Maximum input current | 13.7 A |
4 quadrant operation possible | true |
Option card | communication module- PROFINET |
Pollution degree | 2 |
Prospective line Isc | 5 kA |
Number of HW interfaces serial RS232 | 0.0 |
With sft fct Safe Stop 2 (SS2) | false |
Supporting protocol for TCP/IP | true |
Permitted relative humidity (during transport) | class 2K5 according to EN 60721-3 |
With safety function Safely Limited Speed (SLS) | true |
Number of HW interfaces serial TTY | 0.0 |
Product specific application | complex machines |
Discrete input logic | negative logic (sink) |
With safety function Safe torque off (STO) | true |
Depth | 245.0mm |
Application in industrial area permitted | true |
Supporting protocol for INTERBUS | false |
Design of frequency changer | U converter |
Volume of cooling air | 11.3 m3/h |
Supporting protocol for LON | false |
Linearity error | AQ1: +/- 0.3 % for analog output |
Housing material | plastic |
Number of output phases | 3 |
Maximum deflection under vibratory load (during transport) | 3.5mm at 2...13 Hz |
Width | 60mm |
Supporting protocol for SafetyBUS P | false |
Ambient air transport temperature | -25-70 °C |
Capacity of DC link | 560 µF |
Nominal output current | 9.5 A |
NEMA degree of protection | not applicable |
Power loss static current independent | 111 W |
Maximum acceleration under vibratory load (during storage) | 10 m/s² at 13...200 Hz |
Method of access | slave CANopen |
Permitted relative humidity (during operation) | class 3K5 according to EN 60721-3 |
Maximum output voltage | 500 V |
Speed accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn |
Analogue output number | 1 |
Supporting protocol for BACnet | false |
Number of HW interfaces parallel | 0.0 |
Motor slip compensation | not available in voltage/frequency ratio (2 or 5 points) |
Environmental class (during operation) | class 3S2 according to IEC 60721-3-3 |
Analogue input number | 3 |
Number of inputs- potential-free | 0 |
Discrete input type | DI1...DI6 logic inputs- 24 V DC (30 V) |
Net weight | 3.0 kg |
Synchronous motor control profile | vector control without sensor |
Refresh time | relay output (R2A- R2C): 2 ms |
Asynchronous motor control profile | flux vector control without sensor - Energy Saving |
Supporting protocol for DeviceNet Safety | false |
Supporting protocol for SUCONET | false |
EMC filter | Class C2 EMC filter integrated |
[Us] rated supply voltage | 380...500 V - 15...10 % |
With safety function Safe Stop 1 (SS1) | true |
Operating position | vertical +/- 10 degree |
Supporting protocol for ASI | false |
Electromagnetic compatibility | 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 |
Permitted relative humidity (during storage) | class 1K5 according to EN 60721-3 |
Nominal switching frequency | 4 kHz |
Supporting protocol for KNX | false |
Environmental class (during transport) | class 2S1 according to EN 60721-3 |
With safety function Safe Direction (SDI) | false |
Number of HW interfaces USB | 0.0 |
Relative symmetric network frequency tolerance | 5 % |
Mounting mode | cabinet mount |
Supplier Code | ATV320U40N4B |
Number of HW interfaces serial RS422 | 0.0 |
Supporting protocol for SERCOS | false |
Network frequency | 50...60 Hz |
With safety function Safe Operating Stop (SOS) | false |
Supporting protocol for other bus systems | true |
Network number of phases | 3 phases |
With safety function Safe Position (SP) | false |
Analogue input type | AI2 bipolar differential voltage: +/- 10 V DC- impedance: 30 kOhm- resolution 10 bits |
Maximum acceleration under shock load (during transport) | 150 m/s² at 11 ms |
Communication port protocol | CANopen |
IP degree of protection | IP20 |
Range | Altivar Machine ATV320 |
Overvoltage category | III |
Optical interface present | false |
Number of inputs- bidirectional- not potential-free | 0 |
EMC limit value (complied) | true |
1 phase low current possible | false |
Acceleration and deceleration ramps | U |
Nominal output power | 4.0 kW |
Maximum acceleration under vibratory load (during transport) | 10 m/s² at 13...200 Hz |
Base load current at high overload | 9.5 A |
Accuracy | +/- 2 % AQ1 for a temperature of -10...60 °C analog output |
Supporting protocol for CAN | true |
Power loss per device current dependent | 111 W |
Supporting protocol for PROFINET CBA | false |
Maximum switching current | relay output R1A- R1B- R1C- R2A- R2C on inductive load- cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC |
Height | 325.0mm |
Number of HW interfaces serial RS485 | 1.0 |
Relay output type | configurable relay logic R2C |
Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
Supporting protocol for PROFIBUS | true |
Number of HW interfaces PROFINET | 0.0 |
Regulation loop | adjustable PID regulator |
Maximum output frequency | 0.599 kHz |
Number of HW interfaces other | 1.0 |
Format of the drive | book |
Discrete output number | 3 |
Maximum associated fuse rating | 25.0 A |
Marking | RCM |
Maximum deflection under vibratory load (during storage) | 3.5mm at 2...13 Hz |
Supporting protocol for PROFIsafe | false |
Standards | IEC 61800-5-1 |
Brand Name | Schneider Electric |
With safety function Safe programmable logic | false |
Product certifications | KC |
Braking to standstill | by DC injection |
Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
Supporting protocol for AS-Interface Safety at Work | false |
Number of HW interfaces industrial Ethernet | 0.0 |
Supporting protocol for MODBUS | true |
Transient overtorque | 170-200 % of nominal motor torque |
Maximum acceleration under shock load (during storage) | 150 m/s² at 11 ms |
Product or component type | variable speed drive |
Have questions about this product?
Do you need more information? We are here to help. Click below to contact us now!
Get in touchWe would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
Can't find what you're looking for?
Request now
We can source just about anything, submit a request and we'll get back to you soon.