Schneider Electric ATV950D90N4 variable speed drive, Altivar Process ATV900, ATV950, 90kW, 400 to 480V, with braking unit, IP55
Code: SCHATV950D90N4
Unit of measure:
EACH
Description
ATV950 IP55 90KW 400V/480V VARIABLE SPEE
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
Product destination | synchronous motors |
With safety function Safe brake management (SBC/SBT) | true |
Relative humidity | 5-95 % without condensation conforming to IEC 60068-2-3 |
Data format | 8 bits- configurable odd- even or no parity |
With safety function Safe Speed Monitor (SSM) | false |
Maximum deflection under vibratory load (during operation) | 1.5mm at 2...13 Hz |
Line current | 135.8 A at 480 V (normal duty) |
Environmental class (during storage) | class 1S2 according to EN 60721-3-1 |
Supporting protocol for Data-Highway | false |
Operating element present | true |
Ambient air temperature for operation | 40-50 °C (with derating factor) |
Connector type | 1 RJ45 |
Minimum switching current | relay output R1- R2- R3: 5 mA at 24 V DC |
Electrical connection | line side: screw terminal 95...120mm²/AWG 3/0...250 kcmil |
Supporting protocol for EtherNet/IP | true |
Switching frequency | 2.5...8 kHz with derating factor |
Analogue output type | software-configurable current AQ1- AQ2: 0...20 mA impedance 500 Ohm- resolution 10 bits |
Ambient air temperature for storage | -40-70 °C |
Number of input phases | 3 |
Number of addresses | 1-247 |
Discrete output type | logic output DQ- 0-1 kHz <= 30 V DC 100 mA |
Apparent power | 98.2 kVA at 480 V (heavy duty) |
Exchange mode | half duplex- full duplex- autonegotiation Ethernet IP/Modbus TCP |
Sampling duration | 5 ms +/- 1 ms (DI7- DI8) - pulse input |
Brake chopper integrated | true |
Discrete input number | 10 |
Protection type | short-circuit protection: drive |
Encoder protocol | SSI 24V |
Relative symmetric mains voltage tolerance | 10 % |
Motor power kW | 75.0 kW for heavy duty |
Supporting protocol for DeviceNet | false |
Quantity per set | 1 |
With safety function Safely Limited Position (SLP) | false |
Supporting protocol for INTERBUS-Safety | false |
Supporting protocol for Foundation Fieldbus | false |
Supporting protocol for PROFINET IO | true |
Variant | standard version |
Application in domestic and commercial area permitted | false |
Computer port | true |
Maximum input current | 156.2 A |
4 quadrant operation possible | true |
Local signalling | presence of voltage: 1 LED (red) |
Option card | slot A/slot B/slot C: digital and analog I/O extension module |
Pollution degree | 2 |
Prospective line Isc | 50 kA |
Number of HW interfaces serial RS232 | 0 |
With sft fct Safe Stop 2 (SS2) | false |
Supporting protocol for TCP/IP | true |
Permitted relative humidity (during transport) | class 2K5 according to EN 60721-3 |
With safety function Safely Limited Speed (SLS) | true |
Number of HW interfaces serial TTY | 0 |
Supply | internal supply for digital inputs and STO: 24 V DC (21-27 V)- <200 mA- protection type: overload and short-circuit protection |
Input compatibility | STOA- STOB: discrete input level 1 PLC conforming to IEC 61131-2 |
Product specific application | process for industrial |
Discrete input logic | positive logic (source) (DI7- DI8)- < 0.6 V (state 0)- > 2.5 V (state 1) |
With safety function Safe torque off (STO) | true |
Depth | 375mm |
Application in industrial area permitted | true |
Supporting protocol for INTERBUS | false |
Design of frequency changer | U converter |
Supporting protocol for LON | false |
Linearity error | AQ1- AQ2: +/- 0.2 % for analog output |
Housing material | sheet steel |
Number of output phases | 3 |
Maximum deflection under vibratory load (during transport) | 1.5mm at 2...13 Hz |
Width | 345mm |
Supporting protocol for SafetyBUS P | false |
Ambient air transport temperature | -40-70 °C |
Operating altitude | 1000...4800 m with current derating 1 % per 100 m |
Nominal output current | 173.0 A |
Power loss static current independent | 32.0 W |
Maximum acceleration under vibratory load (during storage) | 10 m/s² at 13...200 Hz |
Method of access | slave Modbus TCP |
Permitted relative humidity (during operation) | class 3K5 according to EN 60721-3 |
Maximum output voltage | 480.0 V |
Analogue output number | 2 |
Relay output number | 3 |
Supporting protocol for BACnet | false |
Number of HW interfaces parallel | 0 |
Transmission frame | RTU |
Motor slip compensation | can be suppressed |
Environmental class (during operation) | class 3S3 according to IEC 60721-3-3 |
Analogue input number | 3 |
Number of inputs- potential-free | 0 |
Discrete input type | STOA- STOB safe torque off- 24 V DC (<= 30 V)- impedance: > 2.2 kOhm |
Transmission rate | 9600 bit/s |
Net weight | 87.7 kg |
Synchronous motor control profile | synchronous reluctance motor |
Refresh time | relay output (R1- R2- R3): 5 ms (+/- 0.5 ms) |
Asynchronous motor control profile | constant torque standard |
Supporting protocol for DeviceNet Safety | false |
Supporting protocol for SUCONET | false |
Maximum THDI | <48 % from 80...100 % of load conforming to IEC 61000-3-12 |
EMC filter | with EMC plate option |
[Us] rated supply voltage | 380...480 V - 15...10 % |
With safety function Safe Stop 1 (SS1) | true |
Operating position | vertical +/- 10 degree |
Supporting protocol for ASI | false |
Electromagnetic compatibility | 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 |
Maximum transient current | 217.5 A during 60 s (heavy duty) |
Permitted relative humidity (during storage) | class 1K5 according to EN 60721-3 |
Nominal switching frequency | 2.5 kHz |
Supporting protocol for KNX | false |
Noise level | 69.9 dB |
Environmental class (during transport) | class 2S1 according to EN 60721-3-2 |
Base load current at low overload | 173.0 A |
With safety function Safe Direction (SDI) | false |
Number of HW interfaces USB | 0 |
Relative symmetric network frequency tolerance | 5 % |
Mounting mode | wall mount |
Supplier Code | ATV950D90N4 |
Number of HW interfaces serial RS422 | 0 |
Supporting protocol for SERCOS | false |
Network frequency | 50...60 Hz |
Type of polarization | no impedance for Modbus serial |
Vibration resistance | 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6 |
With safety function Safe Operating Stop (SOS) | false |
Supporting protocol for other bus systems | false |
Network number of phases | 3 phases |
With safety function Safe Position (SP) | false |
Analogue input type | AI1- AI2- AI3 software-configurable current: 0...20 mA/4...20 mA- impedance: 250 Ohm- resolution 12 bits |
Shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
Maximum acceleration under shock load (during transport) | 150 m/s² at 11 ms |
Insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth |
Communication port protocol | Modbus serial |
Degree of protection | UL type 1 |
IP degree of protection | IP55 |
Range | Altivar Process ATV900 |
Overvoltage category | III |
Optical interface present | false |
Number of inputs- bidirectional- not potential-free | 0 |
Assembly style | enclosed |
EMC limit value (complied) | true |
1 phase low current possible | false |
Acceleration and deceleration ramps | linear adjustable separately from 0.01...9999 s |
Nominal output power | 90.0 W |
Maximum acceleration under vibratory load (during transport) | 10 m/s² at 13...200 Hz |
Base load current at high overload | 145.0 A |
Accuracy | +/- 1 % AQ1- AQ2 for a temperature variation 60 °C analog output |
Supporting protocol for CAN | true |
Power loss per device current dependent | 2104.0 W |
Environmental characteristic | dust pollution resistance class 3S3 conforming to IEC 60721-3-3 |
Supporting protocol for PROFINET CBA | true |
Maximum switching current | relay output R2- R3 on resistive load- cos phi = 1 : 5 A at 30 V DC |
Height | 1250mm |
Number of HW interfaces serial RS485 | 1 |
Relay output type | configurable relay logic R3: sequence relay NO electrical durability 1000000 cycles |
Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
Supporting protocol for PROFIBUS | true |
Continuous output current | 145 A at 2.5 kHz for heavy duty |
Number of HW interfaces PROFINET | 0 |
Regulation loop | adjustable PID regulator |
Maximum output frequency | 599 Hz |
Number of HW interfaces other | 0 |
Discrete output number | 2 |
Device application | industrial application |
Maximum associated fuse rating | 250.0 A |
Marking | CE |
Maximum deflection under vibratory load (during storage) | 1.5mm at 2...13 Hz |
Supporting protocol for PROFIsafe | false |
Standards | IEC 60721-3 |
Brand Name | Schneider Electric |
With safety function Safe programmable logic | false |
Product certifications | CSA |
Braking to standstill | by DC injection |
Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
Supporting protocol for AS-Interface Safety at Work | false |
Number of HW interfaces industrial Ethernet | 2 |
Isolation | between power and control terminals |
Supporting protocol for MODBUS | true |
Physical interface | 2-wire RS 485 |
Maximum acceleration under shock load (during storage) | 150 m/s² at 11 ms |
Product or component type | variable speed drive |
Have questions about this product?
Do you need more information? We are here to help. Click below to contact us now!
Get in touchWe would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
Can't find what you're looking for?
Request now
We can source just about anything, submit a request and we'll get back to you soon.