Schneider Electric ATV630D30M3 variable speed drive, Altivar Process ATV600, ATV630, 30kW, 40hp, 200 to 240V, IP21, UL type 1
Code: SCHATV630D30M3
Unit of measure:
EACH
Description
VARIABLE SPEED DRIVE IP21 30KW 200V 240V
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
Product destination | asynchronous motors |
With safety function Safe brake management (SBC/SBT) | false |
Relative humidity | 5-95 % without condensation conforming to IEC 60068-2-3 |
Data format | 8 bits- configurable odd- even or no parity |
With safety function Safe Speed Monitor (SSM) | false |
Maximum deflection under vibratory load (during operation) | 1.5mm at 2...13 Hz |
Line current | 88.6 A at 240 V (normal duty) |
Environmental class (during storage) | class 1S2 according to EN 60721-3-1 |
Supporting protocol for Data-Highway | false |
Operating element present | true |
Ambient air temperature for operation | 50-60 °C (with derating factor) |
Connector type | RJ45 (on the remote graphic terminal) for Modbus serial |
Minimum switching current | relay output R1- R2- R3: 5 mA at 24 V DC |
Electrical connection | line side: screw terminal 70...120mm²/AWG 1/0...250 kcmil |
Supporting protocol for EtherNet/IP | true |
Switching frequency | 2...8 kHz adjustable |
Analogue output type | software-configurable current DQ-- DQ+: 30 V DC |
Motor starter type | variable speed drive |
Output voltage | <= power supply voltage |
Ambient air temperature for storage | -40-70 °C |
Number of input phases | 3 |
Number of addresses | 1-247 for Modbus serial |
Discrete output type | relay outputs R2A- R2C 30 V DC 5000 mA |
Apparent power | 27.9 kVA at 240 V (heavy duty) |
Frequency resolution | analog input: 0.012/50 Hz |
Power dissipation in W | forced convection: 862 W at 200 V- switching frequency 2.5 kHz |
Exchange mode | half duplex- full duplex- autonegotiation Ethernet/Modbus TCP |
Sampling duration | 5 ms +/- 1 ms (DI5- DI6) - discrete input |
Brake chopper integrated | false |
Discrete input number | 8 |
Protection type | thermal protection: drive |
Relative symmetric mains voltage tolerance | 10 % |
Motor power kW | 30 kW (normal duty) |
Supporting protocol for DeviceNet | false |
Quantity per set | 1 |
With safety function Safely Limited Position (SLP) | false |
Permissible temporary current boost | 1.5 x In during 60 s (heavy duty) |
Supporting protocol for INTERBUS-Safety | false |
Supporting protocol for Foundation Fieldbus | false |
Supporting protocol for PROFINET IO | true |
Variant | standard version |
Application in domestic and commercial area permitted | false |
Computer port | true |
Maximum input current | 104.7 A |
4 quadrant operation possible | false |
Local signalling | 1 LED (red) for presence of voltage |
Option card | communication module- BACnet MS/TP |
Pollution degree | 2 conforming to IEC 61800-5-1 |
Prospective line Isc | 50 kA |
Number of HW interfaces serial RS232 | 0 |
With sft fct Safe Stop 2 (SS2) | false |
Supporting protocol for TCP/IP | true |
Permitted relative humidity (during transport) | class 2K5 according to EN 60721-3 |
With safety function Safely Limited Speed (SLS) | false |
Number of HW interfaces serial TTY | 0 |
Discrete and process manufacturing | water and waste water positive displacement pump |
Supply | internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %- <10 mA- protection type: overload and short-circuit protection |
Input compatibility | STOA- STOB: discrete input level 1 PLC conforming to IEC 61131-2 |
Product specific application | process and utilities |
Enclosure mounting | wall mounted |
Discrete input logic | negative logic (sink) (DI1...DI8)- > 16 V (state 0)- < 10 V (state 1) |
With safety function Safe torque off (STO) | true |
Depth | 323mm |
Application in industrial area permitted | true |
Supporting protocol for INTERBUS | false |
Design of frequency changer | U converter |
Volume of cooling air | 295 m3/h |
Supporting protocol for LON | false |
Linearity error | AO1- AO2: +/- 0.2 % for analog output |
Housing material | sheet steel |
Number of output phases | 3 |
Maximum deflection under vibratory load (during transport) | 1.5mm at 2...13 Hz |
Width | 290mm |
Supporting protocol for SafetyBUS P | false |
Ambient air transport temperature | -40-70 °C |
Operating altitude | 1000...4800 m with current derating 1 % per 100 m |
Capacity of DC link | 11200.0 µF |
Nominal output current | 123.0 A |
Device short name | ATV630 |
NEMA degree of protection | NEMA 1 |
Power loss static current independent | 33.0 W |
Maximum acceleration under vibratory load (during storage) | 10 m/s² at 13...200 Hz |
Method of access | slave Modbus TCP |
Permitted relative humidity (during operation) | class 3K5 according to EN 60721-3 |
Maximum output voltage | 240.0 V |
Analogue output number | 2 |
Relay output number | 3 |
Supporting protocol for BACnet | false |
Number of HW interfaces parallel | 0 |
Transmission frame | RTU |
Motor slip compensation | can be suppressed |
Supply frequency | 50...60 Hz - 5...5 % |
Environmental class (during operation) | class 3S3 according to IEC 60721-3-3 |
Analogue input number | 3 |
Number of inputs- potential-free | 0 |
Discrete input type | DI7- DI8 programmable as pulse input: 0-30 kHz- 24 V DC (<= 30 V) |
Transmission rate | 4800 bps- 9600 bps- 19200 bps- 38.4 Kbps |
Net weight | 56.6 kg |
Specific application | utility |
Synchronous motor control profile | synchronous reluctance motor |
Refresh time | relay output (R1- R2- R3): 5 ms (+/- 0.5 ms) |
Asynchronous motor control profile | variable torque standard |
Supporting protocol for DeviceNet Safety | false |
Supporting protocol for SUCONET | false |
Maximum THDI | <48 % from 80...100 % of load conforming to IEC 61000-3-12 |
EMC filter | without EMC filter |
[Us] rated supply voltage | 200...240 V - 15...10 % |
With safety function Safe Stop 1 (SS1) | false |
Operating position | vertical +/- 10 degree |
Supporting protocol for ASI | false |
Electromagnetic compatibility | radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 |
Maximum transient current | 138.9 A during 60 s (heavy duty) |
Permitted relative humidity (during storage) | class 1K5 according to EN 60721-3 |
Nominal switching frequency | 2.5 kHz |
Supporting protocol for KNX | false |
Noise level | 62.4 dB |
Environmental class (during transport) | class 2S1 according to EN 60721-3-2 |
Base load current at low overload | 123.0 A |
With safety function Safe Direction (SDI) | false |
Number of HW interfaces USB | 0 |
Relative symmetric network frequency tolerance | 5 % |
Mounting mode | wall mount |
Supplier Code | ATV630D30M3 |
Number of HW interfaces serial RS422 | 0 |
Supporting protocol for SERCOS | false |
Network frequency | 50...60 Hz |
Type of polarization | no impedance |
Vibration resistance | 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6 |
With safety function Safe Operating Stop (SOS) | false |
Supporting protocol for other bus systems | false |
Network number of phases | 3 phases |
With safety function Safe Position (SP) | false |
Analogue input type | AI1- AI2- AI3 software-configurable current: 0...20 mA- impedance: 250 Ohm- resolution 12 bits |
Shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
Maximum acceleration under shock load (during transport) | 150 m/s² at 11 ms |
Insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth |
Communication port protocol | Ethernet |
Degree of protection | UL type 1 conforming to UL 508C |
IP degree of protection | IP21 |
Range | Altivar Process ATV600 |
Overvoltage category | III |
Optical interface present | false |
Number of inputs- bidirectional- not potential-free | 0 |
Functionality | full |
EMC limit value (complied) | false |
1 phase low current possible | false |
Acceleration and deceleration ramps | linear adjustable separately from 0.01...9999 s |
Nominal output power | 30.0 kW |
Maximum acceleration under vibratory load (during transport) | 10 m/s² at 13...200 Hz |
Power range | 30-50 kW at 200-240 V 3 phases |
Base load current at high overload | 92.6 A |
Accuracy | +/- 1 % AO1- AO2 for a temperature variation 60 °C analog output |
Supporting protocol for CAN | true |
Power loss per device current dependent | 1246.0 W |
Supporting protocol for PROFINET CBA | true |
Maximum switching current | relay output R1- R2- R3 on inductive load- cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC |
Height | 922mm |
Number of HW interfaces serial RS485 | 1 |
Relay output type | configurable relay logic R2: sequence relay NO electrical durability 100000 cycles |
Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
Supporting protocol for PROFIBUS | true |
Continuous output current | 92.6 A at 2.5 kHz for heavy duty |
Number of HW interfaces PROFINET | 0 |
Type of cooling | forced convection |
Regulation loop | adjustable PID regulator |
Maximum output frequency | 500 kHz |
Number of HW interfaces other | 0 |
Discrete output number | 0 |
Maximum associated fuse rating | 160.0 A |
Safety function | STO (safe torque off) SIL 3 |
Marking | CE |
Maximum deflection under vibratory load (during storage) | 1.5mm at 2...13 Hz |
Supporting protocol for PROFIsafe | false |
Standards | IEC 61800-5-1 |
With safety function Safe programmable logic | false |
Product certifications | UL |
Braking to standstill | by DC injection |
Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
Supporting protocol for AS-Interface Safety at Work | false |
Motor power hp | 30 hp heavy duty |
Number of HW interfaces industrial Ethernet | 1 |
Isolation | between power and control terminals |
Supporting protocol for MODBUS | true |
Physical interface | Ethernet |
Speed drive output frequency | 0.1-500 Hz |
Maximum acceleration under shock load (during storage) | 150 m/s² at 11 ms |
Product or component type | variable speed drive |
Have questions about this product?
Do you need more information? We are here to help. Click below to contact us now!
Get in touchWe would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
Can't find what you're looking for?
Request now
We can source just about anything, submit a request and we'll get back to you soon.