Width | 45mm |
Height | 66mm |
Depth | 70mm |
Brand Name | Schneider Electric |
Depth | 70mm |
Height | 66mm |
Net weight | 0.124 kg |
Range | TeSys Deca |
Thermal protection adjustment range | 0.16-0.25 A |
Weight | 0.124 kg |
Width | 45mm |
Ambient air temperature for operation | -20-60 °C without derating conforming to IEC 60947-4-1 |
Ambient air temperature for storage | -60-70 °C |
Associated fuse rating | 4 A BS for signalling circuit |
Auxiliary contact composition | 1 NO + 1 NC |
Climatic withstand | conforming to IACS E10 |
Compatibility code | LRD |
Connections - terminals | control circuit: screw clamp terminals 2 cable(s) 1-2.5mm² solid without cable end |
Control type | blue push-button: reset |
Device short name | LRD |
Dielectric strength | 1.89 kV at 50 Hz conforming to IEC 60947-1 |
Flame retardance | V1 conforming to UL 94 |
Frequency | 0...400 Hz |
IP Rating | IP20 |
IP degree of protection | IP20 conforming to IEC 60529 |
Mechanical robustness | shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7 |
Mount | Plate, with specific accessories |
Mounting support | under contactor |
Network frequency | 0...400 Hz |
Network type | AC |
Permissible current | 0.22 A at 125 V DC-13 for signalling circuit |
Phase failure sensitivity | tripping current 130 % of Ir on two phase- the last one at 0 |
Product certifications | EAC |
Product compatibility | LC1D18 |
Product name | TeSys Deca |
Product or component type | differential thermal overload relay |
Relay application | motor protection |
Standards | GB/T 14048.4 |
Supplier Code | LRD02 |
Supplier ref | LRD02 |
Temperature compensation | -20-60 °C |
Thermal overload class | class 10A conforming to IEC 60947-4-1 |
Tightening torque | power circuit: 1.7 N.m - on screw clamp terminals |
Tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
Voltage | 690 V |
[Ith] conventional free air thermal current | 5 A for signalling circuit |
[Ue] rated operational voltage | 690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1 |
[Ui] rated insulation voltage | power circuit: 690 V conforming to IEC 60947-4-1 |
[Uimp] rated impulse withstand voltage | 6 kV |
Schneider LC2D09BNE TeSys, TeSys Deca, Reversing contactor, 3P(3 NO), AC-3, 0 to 440V, 9A, 24 to 60VAC/DC coil
TeSys LRD thermal overload relay, 0.25A/690V, thermal setting range 0.16-0.25A, tripping class 10A, for protection of 3-phase motors 0.06kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).