Schneider Electric LR2K0312 Differential thermal overload relay, TeSys LR2 K, TeSys K, 3.7...5.5A, class 10A
Code: SCHLR2K0312
Unit of measure:
EACH
Description
Schneider LR2K0312 Overload Relay, 690VAC/250VDC, 3.7-5.5A, 1NO+1NC, Automatic/Manual Reset, For LC1K, LP1K, LC7K, LP4K Contactors
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
Thermal overload class | class 10A conforming to IEC 60947-4-1 |
Ambient air temperature for operation | -30-60 °C with derating conforming to IEC 60947 |
Current Type | AC/DC |
Supplier ref | LR2K0312 |
Contactor | LC1K, LP1K, LC7K, LP4K |
[Ith] conventional free air thermal current | 6 A for signalling circuit |
Supplier Code | LR2K0312 |
Ambient air temperature for storage | -40-70 °C |
Trip Class | Class 10A |
Network frequency | <= 400 Hz |
Network type | AC |
Terminal Type | Screw Clamp |
Control type | blue push-button: stop and manual reset |
IP degree of protection | IP2X conforming to IEC 60529 |
Range | TeSys |
Flame retardance | requirement 2 conforming to NF F 16-101 |
Item Name | Overload Relay |
Protective treatment | TC conforming to DIN 50016 |
Local signalling | trip indicator (yellow) |
Tightening torque | 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6mm |
Thermal protection adjustment range | 3.7-5.5 A |
Auxiliary contact composition | 1 NO + 1 NC |
Current | 3.7 - 5.5A |
Connections - terminals | screw clamp terminals 1 cable(s) 0.75-4mm²flexible without cable end |
Associated fuse rating | 6 A gG for signalling circuit conforming to IEC 60947 |
Standard | CSA, UL Listed |
Depth | 65mm |
Mounting support | plate- with specific accessories |
Fire resistance | 850 °C conforming to IEC 60695-2-1 |
Voltage | 690 VAC/250 VDC |
Degree of Protection | IP2X |
Height | 58mm |
Width | 45mm |
Operating altitude | 2000 m without derating |
Device short name | LR2K |
Phase failure sensitivity | yes conforming to IEC 60947-4-1 |
Compatibility code | LR2K |
Product compatibility | LP1K |
Mechanical robustness | vibrations NC contact: 2 Gn- 5...300 Hz conforming to IEC 60068-2-6 |
[Ue] rated operational voltage | 250 V DC DC-13 for signalling circuit |
[Ui] rated insulation voltage | power circuit: 750 V conforming to VDE 0110 group C |
Standards | BS 4941 |
Product certifications | CSA |
Brand Name | Schneider Electric |
EAN/UPC | 3389110230567 |
[Uimp] rated impulse withstand voltage | 6 kV |
Power dissipation per pole | 2 W |
Contact Configuration | 1 NO + 1 NC |
Reset Type | Automatic/Manual |
Product name | TeSys LRK |
Relay application | motor protection |
Net weight | 0.145 kg |
Product or component type | differential thermal overload relay |