Description
Schneider LC1D1156U7 TeSys, Contactor, TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 115A, 240V AC 50/60Hz coil, lugs/bars terminals
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 115A/1000V AC-3 (55kW@400V). It provides a 240V 50/60Hz AC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirrror certified), power connection by screw connectors 2 inputs, control connection by screw clamp terminals. For operating rates until 2400 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (120mm width), mounting on 2 DIN-rails or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Features:
• Long durability with high operating rate
• Green Premium product
• Multi sdandards certified makes it possible to wide application
• Easy installation and maintenance with compact design
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
Contactor application | motor control |
Maximum operating rate | 2400 cyc/h at 60 °C |
Non-overlap time | 1.5 ms on energisation between NC and NO contact |
Mount | Plate |
Minimum switching current | 5 mA for signalling circuit |
Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 |
Signalling circuit frequency | 25...400 Hz |
[Ith] conventional free air thermal current | 200 A (at 60 °C) for power circuit |
Supplier Code | LC1D115U7 |
Breaking Capacity | 1100 A |
[Icw] rated short-time withstand current | 120 A - 500 ms for signalling circuit |
Inrush power in VA | 280-350 VA 50 Hz cos phi 0.8 (at 20 °C) |
Hold-in power consumption in VA | 2-18 VA 60 Hz cos phi 0.3 (at 20 °C) |
Motor power kW | 65 kW at 1000 V AC 50/60 Hz (AC-3) |
Safety reliability level | B10d = 10000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Insulation resistance | > 10 MOhm for signalling circuit |
IP degree of protection | IP20 front face conforming to IEC 60529 |
Range | TeSys |
Flame retardance | V1 conforming to UL 94 |
Weight | 2.5 kg |
Overvoltage category | III |
Electrical durability | 0.95 Mcycles 115 A AC-3 at Ue <= 440 V |
Protective treatment | TH conforming to IEC 60068-2-30 |
Protective cover | with |
Pollution degree | 3 |
Tightening torque | control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
Average impedance | 0.6 mOhm - Ith 200 A 50 Hz for power circuit |
Auxiliary contact composition | 1 NO + 1 NC |
[Ie] rated operational current | 115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
Connections - terminals | control circuit: screw clamp terminals 1 1-2.5mm² - cable stiffness: solid without cable end |
Control circuit type | AC at 50/60 Hz |
Associated fuse rating | 200 A gG at <= 690 V coordination type 2 for power circuit |
Depth | 136mm |
Mounting support | rail |
Pole contact composition | 3 NO |
Fire resistance | 850 °C conforming to IEC 60695-2-1 |
Voltage | <= 300 V |
Mechanical durability | 8 Mcycles |
Permissible ambient air temperature around the device | 60-70 °C with derating |
Climatic withstand | conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
Coil technology | built-in bidirectional peak limiting diode suppressor |
Height | 158mm |
Minimum switching voltage | 17 V for signalling circuit |
Poles description | 3P |
Width | 120mm |
Operating altitude | 0...3000 m |
Operating time | 20...50 ms closing |
Device short name | LC1D |
[Uc] control circuit voltage | 240 V AC 50/60 Hz |
Compatibility code | LC1D |
Auxiliary contacts type | type mirror contact 1 NC conforming to IEC 60947-4-1 |
Mechanical robustness | shocks contactor open (6 Gn for 11 ms) |
[Ue] rated operational voltage | power circuit: <= 300 V DC |
Pole Configuration | 3 Pole |
[Ui] rated insulation voltage | power circuit: 600 V UL certified |
Contact compatibility | M13 |
Standards | UL 60335-2-40:Annex JJ |
Control circuit voltage limits | 1...1.15 Uc (55-70 °C):operational AC 50/60 Hz |
Product certifications | CSA |
Brand Name | Schneider Electric |
Heat dissipation | 3-8 W at 50/60 Hz |
[Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947 |
Power dissipation per pole | 7.9 W AC-3 |
IP Rating | IP20 |
Motor power hp | 75 hp at 460/480 V AC 50/60 Hz for 3 phases motors |
Rated breaking capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
Utilisation category | AC-3e |
Net weight | 2.5 kg |
Product or component type | contactor |