Schneider LC1DT20FD TeSys, TeSys Deca, Contactor, 4P(4 NO), AC-1, 0 to 440V, 20A, 110VDC standard coil
TeSys D contactor, 4 poles (4NO), for non-inductive load applications up to 20A/440V AC-1. They can be used to create motor starters for almost any type of application. It provides a 240V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Power contacts have a 20A resistive load rating. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh). Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.80 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
Contactor application | resistive load |
Non-overlap time | 1.5 ms on energisation between NC and NO contact |
Mount | Plate |
Minimum switching current | 5 mA for signalling circuit |
Irms rated making capacity | 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
Signalling circuit frequency | 25...400 Hz |
[Ith] conventional free air thermal current | 10 A (at 60 °C) for signalling circuit |
Supplier Code | LC1DT20U7 |
Breaking Capacity | 250 A |
[Icw] rated short-time withstand current | 61 A 40 °C - 1 min for power circuit |
Inrush power in VA | 70-70 VA 50 Hz cos phi 0.75 (at 20 °C) |
Hold-in power consumption in VA | 7-7 VA 50 Hz cos phi 0.3 (at 20 °C) |
Safety reliability level | B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Insulation resistance | > 10 MOhm for signalling circuit |
IP degree of protection | IP20 front face conforming to IEC 60529 |
Range | TeSys Deca |
Flame retardance | V1 conforming to UL 94 |
Weight | 0.365 kg |
Overvoltage category | III |
Item Name | Contactor |
Protective treatment | TH conforming to IEC 60068-2-30 |
Protective cover | with |
Pollution degree | 3 |
Tightening torque | power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 |
Average impedance | 2.5 mOhm - Ith 20 A 50 Hz for power circuit |
Auxiliary contact composition | 1 NO + 1 NC |
Current | 9A |
[Ie] rated operational current | 20 A (at <60 °C) at <= 440 V AC AC-1 for power circuit |
Connections - terminals | power circuit: screw clamp terminals 1 1-4mm² - cable stiffness: flexible without cable end |
Control circuit type | AC at 50/60 Hz |
Associated fuse rating | 25 A gG at <= 690 V coordination type 1 for power circuit |
Depth | 92mm |
Mounting support | rail |
Pole contact composition | 4 NO |
Fire resistance | 850 °C conforming to IEC 60695-2-1 |
Voltage | <= 300 V |
Mechanical durability | 15 Mcycles |
Permissible ambient air temperature around the device | 60-70 °C with derating |
Climatic withstand | conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
Coil technology | without built-in suppressor module |
Height | 85mm |
Minimum switching voltage | 17 V for signalling circuit |
Poles description | 4P |
Width | 45mm |
Operating altitude | 0...3000 m |
Operating time | 12...22 ms closing |
Device short name | LC1D |
[Uc] control circuit voltage | 240 V AC 50/60 Hz |
Compatibility code | LC1D |
Auxiliary contacts type | type mirror contact 1 NC conforming to IEC 60947-4-1 |
Mechanical robustness | vibrations contactor closed (4 Gn- 5...300 Hz) |
[Ue] rated operational voltage | power circuit: <= 300 V DC |
Pole Configuration | 4 Pole |
[Ui] rated insulation voltage | signalling circuit: 690 V conforming to IEC 60947-1 |
Contact compatibility | M6 |
Standards | EN 60947-5-1 |
Control circuit voltage limits | 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz |
Product certifications | CB |
Brand Name | Schneider Electric |
Heat dissipation | 2-3 W at 50/60 Hz |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
Power dissipation per pole | 1.56 W AC-1 |
IP Rating | IP20 |
Rated breaking capacity | 250 A at 440 V for power circuit conforming to IEC 60947 |
Utilisation category | AC-1 |
Coil Voltage | 240VAC |
Net weight | 0.365 kg |
Product or component type | contactor |