Schneider Electric LC1K0901U7 Contactor, TeSys K, 3P, AC-3/AC-3e,<=440V 9A, aux. 1NC, 230...240V AC coil
Code: SCHLC1K0901U7
Unit of measure:
EACH
Description
Contactor
Brand Name: Schneider
Coil Voltage: 240 VAC
Contact Configuration: 1 NC
Number of Poles: 3
Maximum Load Current: 9 A
Coil Power Rating: 4 kW
Technical Specifications
Looking for something specific? Search with keywords to help filter your required specifications.
Contactor application | resistive load |
Maximum operating rate | 3600 cyc/h |
Minimum switching current | 5 mA for signalling circuit |
Non overlap distance | 0.5mm |
Irms rated making capacity | 110 A AC for signalling circuit conforming to IEC 60947 |
Signalling circuit frequency | <= 400 Hz |
[Ith] conventional free air thermal current | 20 A (at 60 °C) for power circuit |
Supplier Code | LC1K0901U7 |
[Icw] rated short-time withstand current | 85 A 50 °C - 5 s for power circuit |
Maximum Load Current | 9 A |
Inrush power in VA | 30-30 VA (at 20 °C) |
Hold-in power consumption in VA | 4.5-4.5 VA (at 20 °C) |
Safety reliability level | B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Motor power kW | 4 kW at 380...415 V AC 50/60 Hz AC-4 |
Insulation resistance | > 10 MOhm for signalling circuit |
Range | TeSys |
Flame retardance | requirement 2 conforming to NF F 16-102 |
Overvoltage category | III |
Electrical durability | 0.16 Mcycles 20 A AC-1 at Ue <= 690 V |
Item Name | Contactor |
Protective treatment | TC conforming to DIN 50016 |
Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
Auxiliary contact composition | 1 NC |
[Ie] rated operational current | 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
Connections - terminals | screw clamp terminals 2 cable(s) 0.34-1.5mm²flexible with cable end |
Control circuit type | AC at 50/60 Hz |
Associated fuse rating | 10 A gG for signalling circuit conforming to VDE 0660 |
Depth | 57mm |
Pole contact composition | 3 NO |
Coil Power Rating | 4 kW |
Mechanical durability | 10 Mcycles |
Minimum switching voltage | 17 V for signalling circuit |
Height | 58mm |
Poles description | 3P |
Width | 45mm |
Operating altitude | 2000 m without derating |
Operating time | 10...20 ms coil energisation and NO closing |
[Uc] control circuit voltage | 230...240 V AC 50/60 Hz |
Compatibility code | LC1K |
Auxiliary contacts type | type instantaneous 1 NC |
Mechanical robustness | vibrations contactor opened: 2 Gn- 5...300 Hz conforming to IEC 60068-2-6 |
Device application | control |
[Ue] rated operational voltage | signalling circuit: <= 690 V AC <= 400 Hz |
Standards | GB/T 14048.4 |
Control circuit voltage limits | drop-out: >= 0.20 Uc (at <50 °C) |
Product certifications | CCC |
Brand Name | Schneider Electric |
Heat dissipation | 1.3-1.3 W |
[Uimp] rated impulse withstand voltage | 8 kV |
Contact Configuration | 1 NC |
Rated breaking capacity | 110 A at 380...400 V conforming to IEC 60947 |
Utilisation category | AC-4 |
Coil Voltage | 240 VAC |
Number of Poles | 3 |
Product or component type | contactor |
We would love your opinion
Was the information on this page helpful?
Thanks for your feedback!
Can't find what you're looking for?
Request now
We can source just about anything, submit a request and we'll get back to you soon.